{"product_id":"cr-m125dc4l-1svr405613r8300-abb-dc-4-c-o-cr-m-relay","title":"CR-M125DC4L 1SVR405613R8300 ABB DC 4 C\/O CR-M Relay","description":"\u003ch2\u003eABB CR-M125DC4L CR-M Interface Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CR-M125DC4L\u003c\/strong\u003e (Order Code: \u003cstrong\u003e1SVR405613R8300\u003c\/strong\u003e) is a pluggable miniature interface relay from ABB's CR-M series designed for signal isolation and circuit switching in industrial control applications. Operating on a 125 V DC coil control voltage, it provides 4 changeover contacts (4 C\/O, SPDT) rated at 250 V \/ 6 A. The relay incorporates an integrated LED coil status indicator and a manual test button for field commissioning and contact locking.\u003c\/p\u003e\n\u003ch3\u003eContact Ratings and Load Capabilities\u003c\/h3\u003e\n\u003cp\u003eEquipped with silver-nickel (AgNi) contacts, the relay handles switching loads across various utilization categories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC-12 (Resistive AC):\u003c\/strong\u003e 6 A at 230 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC-15 (Inductive AC):\u003c\/strong\u003e 1.5 A at 120 V, 1 A at 230 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-12 (Resistive DC):\u003c\/strong\u003e 6 A at 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-13 (Inductive DC):\u003c\/strong\u003e 2 A at 24 V, 0.1 A at 250 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Architecture and Socket Mounting\u003c\/h3\u003e\n\u003cp\u003eThe relay features flat-pin plug-in connections and an IP40 protection rating. Measuring 21.2 mm x 35.6 mm x 27.5 mm with a net weight of 0.033 kg, it plugs into compatible ABB CR-M sockets for DIN rail mounting in compact control panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCR-M125DC4L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number\u003c\/td\u003e\n\u003ctd\u003e1SVR405613R8300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eCR-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePluggable Miniature Interface Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Configuration\u003c\/td\u003e\n\u003ctd\u003e4 C\/O (4PDT \/ 4 SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver-Nickel (AgNi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicator\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Test Button\u003c\/td\u003e\n\u003ctd\u003eIntegrated (with contact locking function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal \/ Connection Type\u003c\/td\u003e\n\u003ctd\u003eFlat-Pin \/ Plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSocket-mounted (DIN rail via CR-M socket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e21.2 mm x 35.6 mm x 27.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61810-1, UL 508, CAN\/CSA C22.2 No.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What control voltage is required to operate the ABB CR-M125DC4L relay? A: The relay coil operates on a nominal 125 V DC control supply voltage.\u003c\/p\u003e\n\u003cp\u003eQ: How is the CR-M125DC4L mounted inside a control panel? A: The relay features flat-pin terminals that plug into a compatible ABB CR-M socket, enabling DIN rail mounting.\u003c\/p\u003e\n\u003cp\u003eQ: What functions do the integrated LED and test button serve? A: The integrated LED indicates active coil status, while the test button enables manual contact actuation and mechanical contact locking for maintenance testing.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43779754197091,"sku":"CR-M125DC4L 1SVR405613R8300","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/373_5f8583d3-befc-4938-bd0d-35d48ee339e7.jpg?v=1760494718","url":"https:\/\/www.autocontrolglobal.com\/products\/cr-m125dc4l-1svr405613r8300-abb-dc-4-c-o-cr-m-relay","provider":"AutoControl Global","version":"1.0","type":"link"}