{"product_id":"csc-200-honeywell-high-speed-microprocessor-protection-module","title":"CSC-200 Honeywell High-Speed Microprocessor Protection Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CSC-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance, modular digital protection and control unit designed for utility and industrial power systems. This device provides a unified platform for the comprehensive protection of substations, transformers, feeders, and motors. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, equipped with a 32-bit high-speed microprocessor and 14-bit A\/D conversion for precise electrical measurements. Its programmable logic and flexible communication interfaces allow engineers to execute complex protection schemes while maintaining seamless integration with modern smart grids and DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSC-200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit High-speed Microprocessor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Acquisition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-bit A\/D Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical Ethernet, LonWorks, Optical RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 103, CSC-2000 Proprietary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvercurrent, Distance, Differential, UV\/OV, UF\/OF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTime Sync\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGPS, IRIG-B, Network Sync\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−10°C to +55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDielectric Strength: 2kV; Insulation ≥100 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD Interface with 11 Status LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Multi-Function Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CSC-200 integrates overcurrent, differential, and distance protection into a single module. This consolidation eliminates the need for multiple discrete relays, reducing cabinet footprint and simplifying the protection string for feeders and transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Isolation \u0026amp; Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing Optical Ethernet and Optical RS-485 interfaces, the device eliminates electrical interference and ground potential differences common in high-voltage substation environments. This ensures zero signal corruption during high-surge events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32-bit microprocessor executes user-defined graphical logic with high speed and consistency. Engineers can program custom interlocking and breaker control schemes that respond in milliseconds to fault conditions, preventing downstream equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features high-resolution Sequence of Events (SOE) recording and fault detection diagnostics. This allows maintenance teams to perform virtual testing and remote simulations, drastically reducing the time required for root-cause analysis after a trip event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Utility Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to exceed IEC standards for vibration, shock, and collision, the CSC-200 thrives in harsh industrial locations. Its electrical insulation handles surge withstand up to 5kV, guaranteeing reliable operation during atmospheric lightning strikes or switching transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cp\u003eMount the CSC-200 in a centralized control panel or distributed switchgear cabinet. Connect the primary CT and PT inputs to the rear terminals, ensuring all wiring meets local utility safety standards. Utilize the PC-based graphical logic editor to configure protection parameters and communication addresses. For precision time-stamping of events, integrate the unit with a GPS or IRIG-B time source to synchronize the CSC-200 with the wider substation network.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat communication protocols does the CSC-200 support for SCADA integration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device natively supports the IEC 103 protocol as well as CSC-2000 proprietary protocols. This allows for seamless data exchange with most industrial SCADA and energy management systems via Optical Ethernet or RS-485.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this device monitor non-electrical quantities?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The CSC-200 includes inputs for non-electrical quantities, such as temperature or pressure trips from transformer Buchholz relays or oil temperature indicators, providing a complete machinery protection profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the LCD interface configurable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features a standard LCD display for local monitoring and status checks. It includes 11 status LEDs that provide immediate visual confirmation of trips, faults, and communication health without requiring a connected PC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or surplus unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, original Honeywell CSC-200 unit. It arrives in factory-original packaging and carries a full manufacturer-equivalent warranty for substation applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43750705496163,"sku":"CSC-200","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/387.jpg?v=1776239621","url":"https:\/\/www.autocontrolglobal.com\/products\/csc-200-honeywell-high-speed-microprocessor-protection-module","provider":"AutoControl Global","version":"1.0","type":"link"}