DC Power Supply Module | IC200PWR001D GE Fanuc VersaMax
Manufacturer: GE Fanuc
-
Part Number: IC200PWR001D
Condition:New with Original Package
Product Type: Power Supply Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC200PWR001D VersaMax Power Supply Module
The GE Fanuc IC200PWR001D, also cataloged as the IC200PWR001 Power Supply Module, operates as a dedicated hardware component for power conversion and voltage regulation within VersaMax PLC systems. The module steps down nominal 24 VDC input power to regulate regulated 5 VDC and 3.3 VDC buses across the backplane to drive CPU logic and I/O modules.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC200PWR001D |
| Brand | GE Fanuc / Emerson |
| Origin | Factory Standard |
| Weight | 0.11 kg (0.25 lbs) |
| Dimensions | 120 mm W x 90 mm H x 40 mm D |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | 11 W input power (15 VA rating) |
| Input Voltage | 24 VDC (supports 120/240 VAC models in series) |
| Output Voltages | 5 VDC and 3.3 VDC regulated rails |
| Total Output Current | 1.5 A maximum combined |
| 5V Output Current | 1.5 A minus the 3.3 V current drawn |
| 3.3V Output Current | 0.25 A maximum |
| Holdup Time | 10 ms |
| Inrush Current | 20 A at 24 VDC, 25 A at 30 VDC |
| Circuit Protection | Short-circuit, overload, reverse polarity, overvoltage |
| Isolation | Galvanic isolation between input terminals and backplane logic |
Backplane Bus Communication Velocity & Power Distribution
The power supply module mounts directly onto the primary slot of the VersaMax baseplate, delivering regulated voltage rails directly to the internal backplane bus. By maintaining stable DC output voltage during transient voltage dips, the unit preserves backplane bus communication velocity and prevents CPU logic reset conditions. Firmware flash compatibility across backplane nodes remains stable during online program downloads due to low-ripple power distribution.
Frequently Asked Questions
Q: How is the maximum output current shared between the 5 VDC and 3.3 VDC supply rails?
A: The total output current capacity across both rails is 1.5 A maximum. The 3.3 VDC rail can draw up to 0.25 A maximum; any current utilized by the 3.3 VDC bus directly reduces the available current capacity on the 5 VDC rail (5 VDC current = 1.5 A - 3.3 V current used).
Q: What protective measures are integrated to prevent damage from wiring errors during installation?
A: The unit integrates reverse polarity protection on the input terminals along with overcurrent, overload, overvoltage, and short-circuit protection circuits. These circuits automatically limit current flow and isolate internal electronics during abnormal electrical conditions.
Q: Does the power supply support hot-swapping while the baseplate is energized?
A: No. Power must be fully isolated before removing or inserting the power module into the baseplate to prevent electrical arcing across backplane pins and memory corruption of active CPU units.
Field Installation Guidelines
- Mount the module directly onto the VersaMax baseplate attached to a standard 35 mm DIN rail or panel surface, ensuring the lock mechanism engages securely.
- Connect the 24 VDC input conductors using wire sizes sized for an inrush current of up to 25 A. Verify polarity alignment prior to applying power.
- Bond the protective earth (PE) grounding terminal directly to the enclosure ground rail with copper wire (minimum 2.0 mm sq / 14 AWG) to ensure noise immunity and safety compliance.
- Maintain a clearance gap of 50 mm above and below the module housing to allow adequate thermal heat dissipation via convection airflow.