{"product_id":"digital-i-o-expansion-module-ge-multilin-ur4lh","title":"Digital I\/O Expansion Module | GE Multilin UR4LH","description":"\u003ch2\u003eGE Multilin UR4LH Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR4LH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR4LH\u003c\/strong\u003e Digital I\/O Module, operates as a dedicated hardware component for signal expansion, breaker management, and interlocking logic execution within Universal Relay (UR) platform architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR4LH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard UR Chassis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eDigital input and output signal expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Logic and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe UR4LH architecture facilitates I\/O density scaling by providing additional optically isolated digital inputs and high-capacity Form-C relay outputs for the UR relay chassis. The module ensures deterministic signal integrity through robust galvanic isolation between field-side I\/O channels and the internal relay CPU backplane, effectively suppressing electrical noise common in substation environments. It supports high-speed processing of digital status changes, enabling the relay to execute complex interlock sequences and breaker management routines without introducing communication latencies. Furthermore, the module is engineered for seamless firmware flash compatibility with the primary UR CPU, allowing the system to auto-detect and configure the expanded I\/O points upon installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UR4LH require individual channel configuration within the relay settings?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each digital input and relay output must be mapped and configured via the relay's setpoint software. This allows the user to define functional behavior, such as target-blocking, latching logic, or specific alarm annunciation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the galvanic isolation protect the relay backplane?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic isolation employs opto-couplers for inputs and isolation relays for outputs, creating a physical barrier. This prevents hazardous high-voltage transients or ground potential differences from the field wiring from propagating into the sensitive CPU or communication modules.\u003c\/p\u003e\n\u003cp\u003eQ: Is the UR4LH compatible with both conventional and high-speed protection schemes?\u003c\/p\u003e\n\u003cp\u003eA: The module is optimized for industrial-grade signal handling. While it is fully compatible with all standard UR protection algorithms, always verify the specific response time requirements of the protection scheme to ensure that the cumulative logic execution time meets site performance criteria.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Ensure the UR chassis power supply is de-energized before inserting or removing the I\/O module. Follow all site-specific lockout\/tagout procedures to prevent accidental energization during the upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Engagement:\u003c\/strong\u003e Align the UR4LH module with the selected empty slot in the UR chassis. Ensure the board edges are seated firmly in the card guides to prevent mechanical strain on the backplane connector pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination:\u003c\/strong\u003e Terminate field conductors to the rear terminal blocks using proper torque specifications. Ensure all digital input circuits are verified for correct voltage levels before applying power to the relay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e After installation, power on the relay and navigate to the \"I\/O Status\" menu in the device software. Confirm that the module is recognized by the CPU and that all digital inputs correctly reflect the current physical field status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43865399099491,"sku":"UR4LH","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/194._155a4ac8-d2e8-4fb2-883f-b6ec1b0cf86d.jpg?v=1764553366","url":"https:\/\/www.autocontrolglobal.com\/products\/digital-i-o-expansion-module-ge-multilin-ur4lh","provider":"AutoControl Global","version":"1.0","type":"link"}