{"product_id":"digital-input-assembly-51308386-175-cc-tdil01-honeywell","title":"Digital Input Assembly | 51308386-175 CC-TDIL01 | Honeywell","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input I\/O Termination Assembly (IOTA) engineered for the Honeywell Experion PKS C300 controller environment. This module provides the critical physical interface for capturing discrete signals from field-mounted devices such as limit switches, push buttons, and motor status auxiliary contacts. By utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e, the control system receives high-integrity ON\/OFF status data, which is essential for safety interlocking, sequence control, and alarm management.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-availability industrial applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 11 isolated channels to prevent ground loops and field-side electrical interference from affecting the controller backplane. This unit is supplied as 100% brand new and factory-original, featuring a rugged construction that supports continuous operation in harsh G3-rated corrosive environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51308386-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Also referred to as CC-GDIL01 PWA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Digital Input I\/O Termination Assembly (IOTA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 11 Isolated Digital Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e: Dry contact or 24 VDC voltage input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: 24 VDC (Acceptance range 18–30 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Channel-to-channel and channel-to-system galvanic isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Features\u003c\/strong\u003e: Integrated fault detection and communication link monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e: 100 ms typical (Configurable via Experion software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5% to 95% (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e: C300 Series Rack or Carrier installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 127 mm x 35 mm x 147 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.65 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Signal Integrity\u003c\/strong\u003e: The galvanic isolation ensures that a short circuit or surge on a single field contact does not propagate to adjacent channels or the central C300 processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Management\u003c\/strong\u003e: When installed on a redundant baseplate, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01 (51308386-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables seamless signal tracking by both primary and backup controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e: The -175 suffix indicates the inclusion of Honeywell’s high-grade conformal coating, protecting the PWA against moisture, dust, and corrosive airborne contaminants typical in chemical or refining zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CC-TDIL01 (51308386-175) handle 120V AC digital inputs?\u003c\/strong\u003eNo, this specific IOTA is designed for 24 VDC nominal signals. For 120V AC field devices, you must utilize interposing relays or a high-voltage rated digital input module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CC-TDIL01 (51308386-175) hot-swappable?\u003c\/strong\u003eYes, in a redundant C300 configuration, the module can be replaced while the secondary partner maintains active signal monitoring, ensuring zero downtime for the process loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between CC-TDIL01 and CC-GDIL01?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TDIL01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the functional model designation for the termination assembly, while CC-GDIL01 often refers to the internal Printed Wire Assembly (PWA). They are components of the same I\/O channel subsystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44079198077027,"sku":"CC-GDIL01","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/370_e55032a8-0323-4a1c-89d5-9619818ce0e1.jpg?v=1774489039","url":"https:\/\/www.autocontrolglobal.com\/products\/digital-input-assembly-51308386-175-cc-tdil01-honeywell","provider":"AutoControl Global","version":"1.0","type":"link"}