{"product_id":"digital-input-module-yokogawa-adv151-p13-s2","title":"Digital Input Module | YOKOGAWA ADV151-P13 S2","description":"\u003ch2\u003eYOKOGAWA ADV151-P13 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA ADV151-P13 S2\u003c\/strong\u003e serves as the primary \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module utilized to execute discrete ON\/OFF signal acquisition across CENTUM VP, CS 3000, and CS 1000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P13 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (Shipping Weight: 1.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81 x 103 x 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e290 mA max (at 5 VDC), 140 mA max (at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eNo-voltage dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Condition\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 1 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Condition\u003c\/td\u003e\n\u003ctd\u003eGreater than or equal to 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e6 mA +\/- 20 percent (at 24 VDC, 0 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC between input signal and system (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block or MIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Capability\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eField instrument signals enter the digital input circuitry through optocouplers that establish 2 kV AC galvanic isolation between input channels and internal system backplane logic. This isolation topology blocks common-mode voltage spikes and suppresses signal cross-talk across channels in noise-intensive industrial environments. While cold junction compensation (CJC) applies primarily to thermocouple analog loops, the discrete filtering architecture in this module suppresses high-frequency field contact chatter, maintaining stable discrete state logic transfers to the DCS CPU.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can engineers hot-swap the module while system backplane power remains active?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live online hot-swapping inside standard I\/O racks without interrupting communications or power distribution to adjacent operational modules.\u003c\/p\u003e\n\u003cp\u003eQ: What action should plant technicians take if replacing an obsolete ADV151-P13 hardware module?\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa designates the ADV151-P63\/D5A00 Digital Input Module as the direct factory replacement unit for legacy ADV151-P13 series hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module securely into its designated slot on the CENTUM system node I\/O rack until the retaining latches lock into position. Route all field wiring through shielded twisted-pair cables, terminating the cable shields at a central low-impedance earth ground bar. When connecting field conductors to pressure clamp terminal assemblies or MIL connector cables, ensure clean wiring paths isolated from high-voltage AC lines to prevent electromagnetic noise induction.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":46226759123043,"sku":"ADV151-P13 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/894_a0fde577-abbc-47d1-8eae-c884faaad845.jpg?v=1790062430","url":"https:\/\/www.autocontrolglobal.com\/products\/digital-input-module-yokogawa-adv151-p13-s2","provider":"AutoControl Global","version":"1.0","type":"link"}