{"product_id":"digital-output-module-yokogawa-adv551-p00-s2","title":"Digital Output Module | Yokogawa ADV551-P00 S2","description":"\u003ch2\u003eYokogawa ADV551-P00 S2 Digital Output Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV551-P00 S2\u003c\/strong\u003e serves as the primary \u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module utilized to execute 24 VDC current-sink field switching across Yokogawa CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse width output \/ time-proportioning output functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eS2\u003c\/td\u003e\n\u003ctd\u003eStyle S2 revision for updated hardware release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P00 S2 (Base Model: ADV551)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia \/ Japan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.8 mm x 102.2 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 VDC (Backplane); 60 mA at 24 VDC (External)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (External power range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output ON Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF Leakage\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon minus side every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (signal to system); 500 V AC for 1 minute (between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003ePressure-clamp terminal block, AKB331 cable, or MIL cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM VP process control systems utilize galvanic optocoupler isolation arrays to isolate external 24 VDC field load loops from backplane microprocessors. The module breaks its 32 digital output transistor circuits into two isolated groups of 16 channels, each utilizing a common negative power rail. Internal high-speed switching transistors handle status switching, one-shot pulse outputs, and time-proportioning duty cycles down to an 8 ms resolution while maintaining a 2 kV AC dielectric withstand rating between field loops and internal system buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What output timing modes can be configured on individual channels?\u003c\/p\u003e\n\u003cp\u003eA: Channels support standard continuous ON\/OFF status output, one-shot pulse-width outputs ranging from 8 ms to 7,200 seconds, and time-proportioning duty cycles.\u003c\/p\u003e\n\u003cp\u003eQ: How is external loop power distributed across the 32 channels?\u003c\/p\u003e\n\u003cp\u003eA: External 24 VDC control power is supplied to the module's power terminal connections to drive field loads, consuming up to 60 mA internally to power the high-side load driver electronics.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module operate in a fault-tolerant dual-redundant pairing?\u003c\/p\u003e\n\u003cp\u003eA: Yes, two ADV551-P00 S2 modules can install in paired subrack slots on a dual-redundant baseplate to maintain uninterrupted discrete signal switching during hardware maintenance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify that external 24 VDC power supplies and backplane rack power are turned off prior to inserting or extracting the module.\u003c\/p\u003e\n\u003cp\u003eEnsure field wiring harnesses for high-inductive loads (such as large relay coils or solenoid valves) incorporate suppressors or flyback diodes installed near the load to prevent back-EMF voltage spikes from damaging the open-collector output transistors.\u003c\/p\u003e\n\u003cp\u003eConnect external terminal blocks or AKB331 pre-fabricated cables securely using integrated locking screws, and route signal cables separately from high-voltage AC conductors to prevent induced electromagnetic noise.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584601161827,"sku":"ADV551-P00 S2","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/912..jpg?v=1790559529","url":"https:\/\/www.autocontrolglobal.com\/products\/digital-output-module-yokogawa-adv551-p00-s2","provider":"AutoControl Global","version":"1.0","type":"link"}