{"product_id":"digital-output-module-yokogawa-adv551-p60-d5s00","title":"Digital Output Module | Yokogawa ADV551-P60\/D5S00","description":"\u003ch2\u003eYokogawa ADV551-P60\/D5S00 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV551-P60\/D5S00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV551\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for 32-channel discrete switching and pulse-width execution within Yokogawa CENTUM VP and FIO networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADV551\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module (32-channel, 24 VDC, Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput Function\u003c\/td\u003e\n\u003ctd\u003eWith pulse width output function \/ time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware Option\u003c\/td\u003e\n\u003ctd\u003eWith status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic Code\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/D5S00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption Code\u003c\/td\u003e\n\u003ctd\u003eEquipped with ATD5S-00 Pressure Clamp Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV551-P60\/D5S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (Module + Terminal Block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa FIO Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 700 mA at 5 VDC (plus external 24 VDC field supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 digital outputs (current sink type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Permissible range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 VDC (Typical: 50 mA at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 ms (Status Output), \u0026lt;= 10 ms (Mixed\/Pulse Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eCommon-minus configuration every 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (Signal-to-System), 500 V AC (Between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e8 ms to 7,200 s (Resolution: 8 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003eATD5S-00 Pressure Clamp Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Field Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe hardware enforces galvanic isolation between input logic and field terminal circuits, sustaining a 2 kV AC withstand voltage from field channels to the backplane system bus. Operating via a 24 VDC current-sink transistor network, the output stages group into 16-channel common-minus blocks to isolate ground differentials across multi-point actuator loops. Continuous diagnostic loops scan individual channel drivers, presenting real-time status output states across the front-panel LED matrix while maintaining full hardware switching execution down to 3 ms response intervals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary functional difference between the ADV551-P60\/D5S00 and the older ADV551-P10 variant?\u003c\/p\u003e\n\u003cp\u003eA: The P60 suffix incorporates a front-panel status LED display and diagnostic pushbutton for local state verification, while retaining the pulse-width and time-proportional output function of the P10 model without explosion protection ratings.\u003c\/p\u003e\n\u003cp\u003eQ: How does the \/D5S00 option code modify field cabling requirements?\u003c\/p\u003e\n\u003cp\u003eA: The \/D5S00 option provides a direct-mount ATD5S-00 pressure clamp terminal block mounted on the front module connector. This enables direct field conductor terminations on the front panel, eliminating external multi-core cabling and intermediate terminal interface boards.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle pulse-width output timing configurations?\u003c\/p\u003e\n\u003cp\u003eA: The -P firmware engine accepts software-defined pulse durations ranging from 8 ms to 7,200 s. Pulses are processed in strict 8 ms resolution increments with a maximum OFF-state leakage current under 0.1 mA across all 32 current-sinking transistor channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the module straight into an unpopulated FIO rack slot until the backplane connectors seat completely. Secure top and bottom panel mounting screws to establish frame ground continuity before applying power.\u003c\/p\u003e\n\u003cp\u003eWire field conductors directly to the ATD5S-00 pressure clamp terminal block using stranded copper wire sized according to local current demands. Ensure external 24 VDC loop power stays strictly within the 20.4 to 26.4 VDC window under full load conditions (100 mA per channel maximum). Separate field DC output lines from high-voltage AC cables by at least 100 mm inside the control enclosure to prevent electromagnetic coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67662512226403,"sku":"ADV551-P60\/D5S00","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/896_04a1ffaa-cbf6-4faa-8235-e3dc4fa3b0f1.jpg?v=1791422629","url":"https:\/\/www.autocontrolglobal.com\/products\/digital-output-module-yokogawa-adv551-p60-d5s00","provider":"AutoControl Global","version":"1.0","type":"link"}