{"product_id":"digital-output-modules-yokogawa-adv561-p50-centum-vp","title":"Digital Output Modules | Yokogawa ADV561-P50 CENTUM VP","description":"\u003ch2\u003eYokogawa ADV561-P50 Digital Output Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV561-P50\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV561\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for driving field actuators and discrete devices within Yokogawa CENTUM CS and CENTUM VP control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Option Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eADV561\u003c\/td\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse width output function \/ time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV561-P50 (Base Model: ADV561)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32 mm x 120 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e700 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel at 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output ON Voltage\u003c\/td\u003e\n\u003ctd\u003e2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF-State Leakage\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Isolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation (2 kV AC signal to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 ms (status output); \u0026lt;= 10 ms (mixed status\/pulse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Interface\u003c\/td\u003e\n\u003ctd\u003eDedicated cable (AKB337) or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel-to-Channel Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eYokogawa CENTUM VP distributed control architectures isolate field-side power surges from backplane processing units through optocoupler arrays integrated into the output stage. The current-sink transistor network executes high-density switching across 64 discrete channels while maintaining galvanic isolation up to 2 kV AC between output terminals and core system logic. Incorporating cold junction compensation logic elsewhere in analog subsystems alongside isolated digital loops ensures noise-free current-sinking paths for 24 VDC solenoids, relay coils, and indicator panels without signal degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What external power configuration is required to operate the output channels?\u003c\/p\u003e\n\u003cp\u003eA: The channel logic requires an external 24 VDC power supply delivering up to 100 mA to feed field load switching paths.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module generate timing-specific pulse train outputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the -P suffix option enables one-shot pulse width output functions with configurable pulse widths ranging from 8 ms to 7200 s at 8 ms resolution.\u003c\/p\u003e\n\u003cp\u003eQ: Is dual-redundant deployment supported on the I\/O baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, two ADV561 modules can be configured in adjacent slots to provide dual-redundant current-sink output operation across field control loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDisconnect external 24 VDC power supplies prior to mounting or wiring the module to prevent short circuits and component degradation.\u003c\/p\u003e\n\u003cp\u003eRoute field wiring through dedicated AKB337 cables or MIL connector assemblies directly to AED5D terminal boards. Maintain physical separation between 24 VDC discrete output wiring and high-voltage AC power lines within the enclosure wireways.\u003c\/p\u003e\n\u003cp\u003eEnsure all cable connector shield drain wires terminate at a dedicated cabinet earth ground bus. Seat the module firmly into the subrack slot until backplane retention latches engage completely to maintain continuous logic power and bus connectivity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67584319946851,"sku":"ADV561","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/908..jpg?v=1790557997","url":"https:\/\/www.autocontrolglobal.com\/products\/digital-output-modules-yokogawa-adv561-p50-centum-vp","provider":"AutoControl Global","version":"1.0","type":"link"}