{"product_id":"dio32-c-bachmann-bachmann-m1-datasheet-technical-manual","title":"DIO32-C Bachmann Bachmann M1 Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eBachmann DIO32-C Industrial Digital Input\/Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density discrete signal processing in CAN network architectures, the \u003cstrong\u003eBachmann DIO32-C\u003c\/strong\u003e (\u003cstrong\u003eDIO32-C\u003c\/strong\u003e Standalone Digital I\/O Module) provides direct electrical execution of field sensor monitoring and actuator commands. The hardware integrates 32 digital channels that allow independent configuration as either inputs or outputs to handle discrete signaling circuits. The device operates as an autonomous CAN slave transceiver, establishing deterministic fieldbus communication lines back to the master controller station while managing localized electrical terminal states.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDIO32-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 25 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5-6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eBachmann M1 Automation System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Channels\u003c\/td\u003e\n\u003ctd\u003e32 Digital Channels (freely configurable as input or output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2 to 3 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDual CAN bus interfaces for loop-through topology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Fieldbus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes an onboard microcontroller that governs the local firmware execution loop and manages continuous hardware stack operations. The integrated dual CAN interfaces execute hardware-level data link layer arbitration according to standardized industrial protocols, allowing firmware flash compatibility updates directly over the communication bus.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity:\u003c\/strong\u003e The internal registers synchronize I\/O states with the primary processor memory loop via automated polling routines, maintaining consistent transmission rates and low logic propagation latency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e The software structure supports precise masking of individual channel properties, allowing mixing of inputs and outputs on the same physical terminal strip without generating channel cross-talk or timing discrepancies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Loop Integrity:\u003c\/strong\u003e Dedicated non-volatile memory segments contain the active network configuration parameters, ensuring the device returns to its exact assigned node ID and operational state immediately following a hardware reset or power interruption cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the galvanic isolation circuit protect the host network?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates optoelectronic barriers that isolate the 32 field I\/O channels from the internal CAN communication electronics up to 1500 V RMS. This isolates transient overvoltages and ground loops to the physical field terminals, keeping the internal logic rail stable.\u003c\/p\u003e\n\u003cp\u003eQ: What are the configuration constraints for the 32 discrete channels?\u003c\/p\u003e\n\u003cp\u003eA: There are no hardwired grouping constraints. Each channel can be assigned as a 24 VDC digital input (drawing 2 to 3 mA) or a 24 VDC digital output (sourcing up to 0.5 A) via the system configuration software tools prior to runtime execution.\u003c\/p\u003e\n\u003cp\u003eQ: How does the loop-through CAN architecture affect network topology?\u003c\/p\u003e\n\u003cp\u003eA: The integration of two separate physical CAN interfaces allows direct daisy-chain cabling configurations between adjacent slave nodes. This layout eliminates external junction blocks and limits stub-line signal reflections on high-velocity data links.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Fix the chassis securely onto a standard 35 mm DIN-rail or within the designated M1 rack enclosure. Ensure the mounting clip engages fully with the rail matrix to prevent displacement under mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Grounding:\u003c\/strong\u003e Terminate all 24 VDC field lines using standard industrial wire sizes matching the terminal block specifications. Route the CAN communication cables separately from high-voltage AC power lines or variable speed drive output cables to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Continuity:\u003c\/strong\u003e Connect the CAN cable shield directly to the functional earth ground terminal at a single point inside the enclosure. Maintain the physical continuity of the shield across all loop-through connections while preventing unintended multiple ground paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e Maintain minimum clearances of 20 mm above and below the housing ventilation slots to ensure unhindered passive convection cooling across the internal circuitry within the specified operating temperature range of -30 to +60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43881663823971,"sku":"DIO32-C","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/41_9fe739ef-cc79-40df-a75a-0304973113e4.jpg?v=1765338260","url":"https:\/\/www.autocontrolglobal.com\/products\/dio32-c-bachmann-bachmann-m1-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}