{"product_id":"do561-abb-s500-eco-digital-output-module-1tne968902r2201","title":"DO561 ABB S500-eCo Digital Output Module 1TNE968902R2201","description":"\u003ch2\u003eABB DO561 S500-eCo Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DO561\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO561\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete DC load control within AC500-eCo PLC platforms. Configured to transfer internal logical states into physical switching operations, the module commands up to 8 field actuators or solenoids via integrated transistor outputs wired in a 1-wire configuration across a single electrical group.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO561 (Part Number: 1TNE968902R2201)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.118 kg net (0.22 kg gross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 mm x 74 mm x 135 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (horizontal mounting), 0 to +40 deg C (vertical mounting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0 to 1.6 W maximum power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Digital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor (DC switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage (Uout)\u003c\/td\u003e\n\u003ctd\u003e24 VDC rated (operating range: 20.4 to 28.8 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 0.5 A per channel, 4 A maximum per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Time\u003c\/td\u003e\n\u003ctd\u003e0 to 1: 50 us, 1 to 0: 200 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Grouping\u003c\/td\u003e\n\u003ctd\u003e1 group of 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between output group and internal logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC process supply via UP terminal (20.4 to 28.8 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eClamps surge voltages up to 35 VDC for 0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Integration Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe hardware executes discrete switching through dense internal transistor matrices, matching the firmware flash compatibility criteria of the AC500-eCo processor series. The module directly couples with the internal system backplane, sending individual status updates while relying on the native bus velocity protocols to maintain deterministic timing.\u003c\/p\u003e\n\u003cp\u003eWhen remote configurations utilize Profinet or EtherNet\/IP deterministic networks, the module updates the output image table within microsecond intervals, minimizing propagation delays. Load switching draws from the 24 VDC process voltage applied across the UP and ZP terminals. To avoid internal channel damage during high-current anomalies or short-circuit transients, you must place an external 3 A fast-acting fuse in series with the process supply path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the dynamic response times of the transistor outputs when switching states?\u003c\/p\u003e\n\u003cp\u003eA: The hardware delivers an output turn-on delay (0 to 1) of 50 us and a turn-off delay (1 to 0) of 200 us, enabling quick execution for high-speed industrial applications.\u003c\/p\u003e\n\u003cp\u003eQ: Is individual channel-to-channel isolation provided within the 8-point output block?\u003c\/p\u003e\n\u003cp\u003eA: No, the 8 channels share a common reference potential within a single electrical group. The module provides galvanic isolation exclusively between that entire output group and the internal control logic.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DO561 be hot-swapped while the AC500-eCo backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swapping this module is not permitted. System power and process supply voltage must be fully isolated before inserting or removing the module to prevent electrical damage or unexpected state execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting Stability:\u003c\/strong\u003e Mount the unit on standard TH35 symmetric DIN rails. Secure the bottom locking mechanism completely to prevent intermittent backplane connectivity from mechanical shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Standards:\u003c\/strong\u003e Terminate inductive load suppressors close to the actuator. Route the 24 VDC process supply through twisted cables and keep signal lines physically isolated from high-voltage AC motor wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Integration:\u003c\/strong\u003e Use pluggable terminal connectors for field wiring interfaces. Ensure all wires are stripped to the correct length and secured to prevent high-resistance connection points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Space Requirements:\u003c\/strong\u003e Maintain an unobstructed space envelope above and below the housing. If mounting vertically, lower the maximum operating limit to +40 deg C to offset diminished airflow.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44406718562403,"sku":"DO561 1TNE968902R2201","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/708.jpg?v=1785141171","url":"https:\/\/www.autocontrolglobal.com\/products\/do561-abb-s500-eco-digital-output-module-1tne968902r2201","provider":"AutoControl Global","version":"1.0","type":"link"}