{"product_id":"ds200lppag1aaa-ge-turbine-line-protection-module-original","title":"DS200LPPAG1AAA GE Turbine Line Protection Module - Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE DS200LPPAG1AAA serves as the primary Line Protection Power Amplifier within the Speedtronic Mark V control architecture. This high-precision board amplifies critical turbine control signals while providing a robust interface for protective relays. It ensures the integrity of command signals sent to turbine actuators and monitoring systems. By integrating signal conditioning and amplification on a single PCB, this module maintains the safety and operational efficiency of large-scale gas and steam turbines in power generation and heavy industrial facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following data details the engineering parameters of the DS200LPPAG1AAA amplifier board:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLine Protection Power Amplifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Backplane Bus Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG1AAA High-Performance Revision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 cm x 24 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200LPPAG1AAA optimizes turbine performance by addressing specific environmental and technical challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board filters and stabilizes low-level control signals before amplification, preventing erratic turbine behavior caused by electrical noise or signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Drive Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard power amplifier delivers sufficient current to drive heavy-duty protective relays and solenoid valves, ensuring rapid response during emergency trip sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE utilizes industrial-grade heat dissipation components that allow the board to operate continuously at +60°C, making it suitable for unconditioned control rooms near turbine enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Backplane Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DS200LPPAG1AAA utilizes standard Mark V rack connectors, eliminating the need for external wiring harnesses and reducing the risk of connection failures in high-vibration environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200LPPAG1AAA replace a DS200LPPAG1A module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the G1AAA revision includes enhanced component tolerances and backward compatibility. It directly replaces the base G1A version without requiring hardware modifications to the Mark V rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary indicators of a malfunctioning amplifier board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians typically observe signal clipping, intermittent relay chatter, or \"Voter Mismatch\" alarms in the Mark V diagnostic software. If the amplification stage fails, the turbine control system may trigger a protective trip to ensure safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board require calibration upon installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DS200LPPAG1AAA features factory-set gain parameters; however, engineers should verify the output levels using the Mark V \u0026lt;I\u0026gt; data processor to ensure the signal matches the specific turbine actuator requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board compatible with both Gas and Steam turbine controls?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DS200LPPAG1AAA functions as a universal line protection amplifier within the Speedtronic Mark V family, supporting both types of turbine power generation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44097211727971,"sku":"DS200LPPAG1AAA","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/476._c72c11bf-0f60-4ef3-8c11-925031c128a7.jpg?v=1775113795","url":"https:\/\/www.autocontrolglobal.com\/products\/ds200lppag1aaa-ge-turbine-line-protection-module-original","provider":"AutoControl Global","version":"1.0","type":"link"}