{"product_id":"ds200lrpag1a-ge-mark-v-speedtronic-tmr-protection-card","title":"DS200LRPAG1A GE Mark V Speedtronic TMR Protection Card","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Line Protection and Analog I\/O Board developed by GE (General Electric) for the Mark V Speedtronic turbine control system. This module serves as a critical interface for gas and steam turbine operations, performing high-speed analog signal conditioning and protective logic functions. By processing sensor data from LVDTs, thermocouples, and vibration sensors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides real-time monitoring and executes protective actions within 2 milliseconds in the event of electrical faults. Its design supports both Simplex and Triple Modular Redundancy (TMR) configurations, ensuring the highest levels of safety and operational availability in power generation and heavy industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ General Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLRPA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLine Protection and Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLVDT, Thermocouple, 4–20 mA, Vibration, Pulse\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eServo Valve, Relay Driver, 4–20 mA, Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 2 ms (Fault detection to protective action)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTMR (2\/3 voting logic) or Simplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 Vrms (Channel-to-system)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330 mm × 178 mm × 2 mm (6U Slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +70 °C (Industrial grade with conformal coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering and Operational Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Protection\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for safety-critical loops. The onboard logic can trip or modulate actuators nearly instantaneously (≤2ms) when signal thresholds are exceeded, protecting multi-million dollar turbine assets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Signal Conditioning\u003c\/strong\u003e: This board is an authoritative solution for multi-signal environments. It eliminates the need for external converters by natively handling high-frequency vibration signals and low-voltage thermocouple readings on a single PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTMR Architecture\u003c\/strong\u003e: When deployed in a Triple Modular Redundant system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eparticipates in 2-out-of-3 voting. This expertise ensures that a single component failure does not cause a nuisance trip or compromise the protective functions of the turbine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Troubleshooting\u003c\/strong\u003e: Integrated LEDs provide immediate visual feedback on board status. For deeper analysis, the Mark V diagnostic software can access the board's internal registers to monitor temperature, fuse integrity, and signal overflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary applications for the DS200LRPAG1A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is primarily utilized in GE gas and steam turbine control panels (Mark V series) within power plants, oil refineries, and large-scale industrial manufacturing sites.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the board handle harsh industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200LRPAG1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures high-grade conformal coating to protect against moisture, dust, and chemical contaminants. Its wide operating temperature range ensures stability in extreme climates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board replace a DS200LRPA board with a different suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 'G1A' suffix denotes a specific group and revision level. While many Mark V boards are backward compatible, it is a professional best practice to verify the specific configuration jumpers and PROM versions before installation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44071480721507,"sku":"DS200LRPAG1A","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/340._c8b4279a-4fcf-4bcf-b401-5dfb53afb92a.jpg?v=1773987599","url":"https:\/\/www.autocontrolglobal.com\/products\/ds200lrpag1a-ge-mark-v-speedtronic-tmr-protection-card","provider":"AutoControl Global","version":"1.0","type":"link"}