DS200RTBAG1AHC GE EX2000 Signal Conditioning Relay Boards
DS200RTBAG1AHC GE EX2000 Signal Conditioning Relay Boards
DS200RTBAG1AHC GE EX2000 Signal Conditioning Relay Boards
/ 3

DS200RTBAG1AHC GE EX2000 Signal Conditioning Relay Boards

  • Manufacturer: GE Fanuc

  • Part Number: DS200RTBAG1AHC

  • Condition:New with Original Package

  • Product Type: Relay Terminal Boards

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE DS200RTBAG1AHC Speedtronic Relay Terminal Board

The GE DS200RTBAG1AHC, also cataloged as the DS200RTBAG1 Relay Terminal Board, operates as a dedicated hardware component for signal conditioning, relay driving, and I/O termination within Speedtronic EX2000 and DS200 turbine control platforms.

Hardware Specifications

Parameter Specification
Model DS200RTBAG1AHC
Brand GE
Origin USA / Global Manufacturing
Weight 0.5 kg
Dimensions 50 x 50 x 25 mm
Operating Temp -40 deg C to +70 deg C
Power Consumption 24 VDC +/-10% input power supply
Architecture Relay Terminal Board / Signal Conditioning Module with multi-layer PCB design
Signal Handling Analog (transducer signals, current/voltage) and Digital (status monitoring, relay control) I/O
Redundancy Supports simplex, duplex, and triplex redundant architecture configurations
Communication Modbus RTU interface for DCS and plant automation integration
Enclosure Protection Stainless steel housing rated to IP65 ingress protection
Certifications CE and RoHS compliant

Backplane Bus Communication Velocity & Deterministic Network Connectivity

The GE DS200RTBAG1AHC routes field transducer signals and relay control outputs while facilitating Modbus RTU communication with external distributed control networks. Driven by high-density multi-layer PCB traces and removable physical connectors, the board maintains consistent signal execution across triplex redundant bus configurations without incurring transaction delays. Onboard signal conditioning circuits isolate analog loops from relay driving stages, maintaining firmware flash compatibility and signal integrity across the EX2000 backplane architecture.

Frequently Asked Questions

Q: How does the DS200RTBAG1AHC maintain signal execution integrity across redundant turbine control architectures? A: The circuit board incorporates dedicated channel paths that interface seamlessly with simplex, duplex, and triplex redundant system buses, delivering synchronized relay actuation and feedback.

Q: What mechanisms protect internal components from dust, moisture, and industrial contaminants? A: The assembly features a stainless steel housing with an IP65 protection rating, preventing dust ingress and liquid contact from affecting field signal conditioning paths.

Q: Can both discrete control loops and variable transducer signals terminate on this single board? A: Yes, the module accepts analog current/voltage input signals as well as digital status and relay driving outputs through its removable terminal connectors.

Field Installation Guidelines

To prevent electrical noise, ground loops, and mechanical strain during field installation, perform the following mounting procedures:

  • Mount the module enclosure securely to panel surfaces, tightening panel fasteners to ensure the IP65 stainless steel chassis aligns properly against structural supports.
  • Connect the main protective earth wire directly from the terminal grounding point to the central panel cabinet earth rail to establish low-impedance EMI shielding.
  • Fully seat all removable terminal connectors before torquing terminal screws to ensure secure pin contact and prevent bent header connections.
  • Route 24 VDC power wiring and discrete relay output lines in separate wire trays away from sensitive low-level analog input cables.
  • Verify that field supply voltages remain within the specified 24 VDC +/-10% operating threshold under maximum relay drive load.