{"product_id":"ds200rtbag3aeb-ge-speedtronic-mark-v-relay-terminal-board","title":"DS200RTBAG3AEB GE Speedtronic Mark V Relay Terminal Board","description":"\u003ch2\u003eGeneral Electric DS200RTBAG3AEB Mark V Relay Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for hardwired relay switching and signal distribution in Speedtronic Mark V and EX2000 excitation control architectures, the \u003cstrong\u003eGeneral Electric DS200RTBAG3AEB\u003c\/strong\u003e (\u003cstrong\u003eDS200RTBAG3A\u003c\/strong\u003e Relay Terminal Board) provides direct physical\/electrical execution across high-density auxiliary control outputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200RTBAG3AEB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (24 VDC \/ 125 VDC control power input via CPH and CPN stab connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark V \/ Mark VI Speedtronic Turbine Control, EX2000 Excitation System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e52 terminals (52 to 96 terminals depending on revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003e10 Form C relays (7 DPDT relays with 2 Form C contacts, 3 relays with 4 Form C contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 3 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e2500 VAC field-to-control isolation (optically isolated drivers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003e24 onboard 3 A fuses with blown-fuse LED indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Board Coating\u003c\/td\u003e\n\u003ctd\u003eConformal coating (Humiseal 1B73)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic LEDs\u003c\/td\u003e\n\u003ctd\u003eRelay state, block-level, and communication status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connectors\u003c\/td\u003e\n\u003ctd\u003eCPH, CPN stabs; RPL, OPTPL connectors; pluggable connectors C1PL-C5PL, Y9PL-Y37PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Inputs\/Outputs\u003c\/td\u003e\n\u003ctd\u003eSupports analog (4-20 mA, 0-10 V), digital inputs\/outputs, thermocouples, RTDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Certifications\u003c\/td\u003e\n\u003ctd\u003eIEC 61511 SIL 2 compliant, IEC 60079-14 Zone 2 hazardous area approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences and Deterministic Execution\u003c\/h3\u003e\n\u003cp\u003eThe DS3800 series and DS200 series terminal architectures route real-time contact commands through RPL and OPTPL ribbon connectors directly to the LAN I\/O Terminal Board (LTB). Optical isolation barriers rated at 2500 VAC isolate field inductive loads from the internal system backplane, preventing switching spikes from degrading backplane bus communication velocity across central processor racks. The board handles local relay driver execution independently, preserving deterministic scan cycles across high-density I\/O channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the DS200RTBAG3AEB protect system electronics from field-side electrical noise?\u003c\/p\u003e\n\u003cp\u003eA: Optical drivers isolate incoming control logic from output contact drivers, while a 2500 VAC field-to-control isolation barrier blocks ground loops and high-voltage inductive surges from entering the main backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What contact configurations are integrated on the board relay array?\u003c\/p\u003e\n\u003cp\u003eA: The board incorporates 10 total relays structured in a hybrid configuration, featuring 7 DPDT relays (2 Form C contacts each) and 3 relays with 4 Form C contacts each.\u003c\/p\u003e\n\u003cp\u003eQ: What physical indicators signal a fuse failure on output channels?\u003c\/p\u003e\n\u003cp\u003eA: Onboard diagnostic light-emitting diodes (LEDs) illuminate adjacent to any of the 24 individual 3 A fuses when an overcurrent event opens the protective trace.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the DS200RTBAG3AEB securely on the cabinet frame standoff pillars within the Mark V control enclosure or EX2000 exciter rack. Tighten all chassis mounting screws to establish frame grounding through the grounded mounting pads.\u003c\/p\u003e\n\u003cp\u003eConnect control power wiring to the CPH and CPN stab connectors. Wire field devices directly to the 52 screw terminals, stripping conductors to standard length to prevent exposed wire contact. Route low-voltage signal cabling through the RPL and OPTPL connectors, maintaining separate wire runs from high-current relay output lines to minimize inductive cross-talk.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44546310504547,"sku":"DS200RTBAG3AEB","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/225.1_288520d6-7520-47e3-a2ed-73f0de518b4b.jpg?v=1788340110","url":"https:\/\/www.autocontrolglobal.com\/products\/ds200rtbag3aeb-ge-speedtronic-mark-v-relay-terminal-board","provider":"AutoControl Global","version":"1.0","type":"link"}