DS200RTBAG5AHC GE Mark V Relay Terminal Boards
DS200RTBAG5AHC GE Mark V Relay Terminal Boards
DS200RTBAG5AHC GE Mark V Relay Terminal Boards
/ 3

DS200RTBAG5AHC GE Mark V Relay Terminal Boards

  • Manufacturer: GE Fanuc

  • Part Number: DS200RTBAG5AHC

  • Condition:New with Original Package

  • Product Type: Relay Terminal Boards

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE DS200RTBAG5AHC Mark V Relay Terminal Board

The GE DS200RTBAG5AHC, also cataloged as the DS200RTBAG5A Relay Terminal Board, operates as a dedicated hardware component for relay output interface execution within Mark V Speedtronic platforms. This terminal board receives low-level switching logic from host controllers across the backplane bus, energizing multiple onboard form-C relays (typically 10 to 12 channels) to drive external contactors, alarm annunciators, and protective trip circuits. Equipped with integrated fuse arrays, diagnostic status LEDs, and jumper-configurable burden resistor selection, the assembly isolates internal rack electronics from field electrical transients and high-voltage AC/DC switching loads.

Suffix Breakdown & Model Matrix

The suffix breakdown for the DS200RTBAG5AHC designates specific PCB functional revisions, artwork layout levels, and protective coating options within the GE Mark V platform:

  • DS200: Standard Mark V system panel and rack-mounted PCB card identifier.
  • RTBA: Functional acronym designating the Relay Terminal Board (RTBA).
  • G5A: Group 5 artwork and circuit design revision baseline.
  • HC: Conformal coating designation and specific high-reliability component revision.

Hardware Specifications

Parameter Specification
Model DS200RTBAG5AHC
Brand GE (General Electric)
Origin United States (USA)
Weight 1.2 kg
Dimensions 330 mm x 280 mm (Standard Mark V rack size)
Operating Temp 0 to +60 deg C
Power Consumption Powered via 24 VDC control supply from system PSU
Series Mark V Speedtronic
Module Type Relay Terminal Board (RTBA)
Relay Channels Multiple Form-C relays (10 to 12 channels)
Contact Ratings 115 VAC / 230 VAC, 2 to 5 A (relay-dependent)
Wiring Interface Screw barrier terminals for field wiring
Circuit Protection Integrated fuse protection on relay branch circuits
Diagnostics LED indicators for relay coil status and fuse condition
Storage Temp -40 to +85 deg C

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The DS200RTBAG5AHC maintains direct physical link pathways with host turbine control cores, ensuring high backplane bus communication velocity during critical tripping and interlock sequences. Onboard coil-driver isolation circuits decouple contact switching transients from the primary bus logic, preventing electromagnetic interference from degrading processor operations. The board maintains complete firmware flash compatibility across all Mark V Speedtronic executive software versions, enabling real-time relay state polling and synchronized fault diagnostic reporting.

Frequently Asked Questions

Q: Can field technicians service or replace onboard fuses without removing field screw terminal wiring?

A: Yes, the onboard fuse holders sit on the front face of the board assembly, allowing fast visual inspection via diagnostic LEDs and direct fuse replacement without disconnecting field wiring harnesses.

Q: Is hot-swapping permitted on the DS200RTBAG5AHC during active turbine execution?

A: No, complete rack de-energization and field contact power isolation are required prior to module extraction or insertion to prevent unexpected contact chatter, relay state corruption, or arc flash across terminal screws.

Q: How are individual relay channels configured for fail-safe or auxiliary trip functions?

A: Technicians set onboard hardware jumpers and switches prior to power-up to establish relay coil assignment, contact sensing polarity, and burden resistor selection according to cabinet engineering drawings.

Field Installation Guidelines

Safety Isolation and Energy Control: Isolate and tag out all 24 VDC system power supplies and high-voltage AC/DC field contact loops connected to the board prior to installation or maintenance.

Mechanical Mounting and Grounding: Align the PCB with the internal rack guide tracks. Insert the card into the slot until the backplane connectors seat completely, then fasten all retaining screws to establish low-impedance chassis ground continuity.

Field Wiring and Terminal Torque: Secure incoming field conductors to the screw terminal blocks using spade or ring lugs. Torque terminal screws according to panel specifications, and route AC switching lines in separate wire ducts away from sensitive low-voltage DC signals to suppress noise coupling.