{"product_id":"ds200tbqbgiacb-general-electric-mark-v-analog-termination-card","title":"DS200TBQBGIACB General Electric Mark V Analog Termination Card","description":"\u003ch2\u003eGeneral Electric DS200TBQBGIACB Mark V Analog Termination Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200TBQBGIACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TBQB\u003c\/strong\u003e Analog Termination Board, operates as a dedicated hardware component for signal termination and field wiring interfacing within GE Speedtronic Mark V turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric product identifier \u003cstrong\u003eDS200TBQBGIACB\u003c\/strong\u003e breaks down into specific functional and revision codes according to GE Speedtronic manufacturing standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS200\u003c\/strong\u003e: Standard GE Speedtronic board class and base platform designator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTBQB\u003c\/strong\u003e: Analog Termination Board functional hardware architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1\u003c\/strong\u003e: Group 1 hardware manufacturing configuration series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Functional circuit revision identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB\u003c\/strong\u003e: Artwork layout modification revision code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQBGIACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e267 mm x 216 mm x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC from backplane at 200 mA to 400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Channels\u003c\/td\u003e\n\u003ctd\u003eMultiple analog and digital I\/O points (24 to 48 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V between field wiring and system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated screw terminals and ribbon cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\/Mounting\u003c\/td\u003e\n\u003ctd\u003eCabinet rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Backplane \u0026amp; Deterministic Networking\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200TBQBGIACB\u003c\/strong\u003e executes low-latency signal distribution between field sensors, actuators, and central Mark V processing cores. The card receives analog voltage and current loops from external field devices, routes them through onboard filter circuits, and delivers scaled parameters to the backplane.\u003c\/p\u003e\n\u003cp\u003eThe board maintains tight synchronization across high-density I\/O channels without introducing backplane bus latency. Firmware flash compatibility validation prevents hardware mismatches across connected processor cards. Integrated surge suppression and 1500 V isolation barriers safeguard sensitive bus logic against ground loops and field transients, maintaining signal integrity under severe electrical noise conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the DS200TBQBGIACB board connect field sensor wiring to the Mark V control system?\u003c\/p\u003e\n\u003cp\u003eA: Field cables wire directly into the onboard screw terminal blocks. Internal traces route these signals through protective filter networks and output them via high-density ribbon cables to adjacent Mark V processor cards.\u003c\/p\u003e\n\u003cp\u003eQ: Is live hot-swapping allowed for the DS200TBQBGIACB module during active turbine operation?\u003c\/p\u003e\n\u003cp\u003eA: No, live removal or insertion is strictly prohibited. Engineers must isolate and de-energize cabinet power supplies prior to board installation or removal to avoid backplane voltage spikes and unexpected control trips.\u003c\/p\u003e\n\u003cp\u003eQ: What protection measures prevent high-voltage surges on field lines from damaging the backplane?\u003c\/p\u003e\n\u003cp\u003eA: Onboard surge suppression networks and a 1500 V galvanic isolation barrier separate the field screw terminals from internal system logic and backplane communication paths.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the DS200TBQBGIACB card into the dedicated Mark V cabinet rack slot, securing all mounting hardware to verify metal-to-metal chassis grounding. Ensure ambient cabinet operating temperatures remain within the -30 deg C to +70 deg C envelope with non-condensing relative humidity between 5% and 95%.\u003c\/p\u003e\n\u003cp\u003eStrip field conductors appropriately and torque terminal screws firmly to maintain reliable low-resistance connections. Route analog signal lines separately from high-voltage AC power wiring to prevent inductive coupling. Ground cable shields at a single chassis point and confirm power isolation before servicing any terminal connections.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44442539688035,"sku":"DS200TBQBGIACB","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/445._c9869982-fc05-4dd0-a715-6743845e7cfb.jpg?v=1785910794","url":"https:\/\/www.autocontrolglobal.com\/products\/ds200tbqbgiacb-general-electric-mark-v-analog-termination-card","provider":"AutoControl Global","version":"1.0","type":"link"}