Dual Right Cable Extender | Emerson KJ4001X1-NA1 DeltaV DCS
Dual Right Cable Extender | Emerson KJ4001X1-NA1 DeltaV DCS
Dual Right Cable Extender | Emerson KJ4001X1-NA1 DeltaV DCS
/ 3

Dual Right Cable Extender | Emerson KJ4001X1-NA1 DeltaV DCS

  • Manufacturer: Emerson

  • Part Number: KJ4001X1-NA1 ABRES2T0200B

  • Condition:New with Original Package

  • Product Type: Carrier Expansion Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson KJ4001X1-NA1 DeltaV Extension Unit

The Emerson KJ4001X1-NA1, also cataloged as the KJ4001X1-NA1 Dual Right Cable Extender, operates as a dedicated hardware component for LocalBus signal and power routing within Emerson DeltaV DCS platforms.

Hardware Specifications

Parameter Specification
Model KJ4001X1-NA1
Brand Emerson
Origin USA
Weight 2 kg
Dimensions Standard DeltaV carrier extender module
Operating Temp -40 to +70 deg C
Power Consumption 12 VDC (8 A) LocalBus bus power limit
System Compatibility Emerson DeltaV DCS
Function Extends LocalBus communication and power to right-side carriers
Relative Humidity 5% to 95% non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3 compliant
Ingress Protection IP20
Shock Resistance 10 g half-sine wave for 11 ms
Vibration Resistance 1 mm P-P (5-16 Hz), 0.5 g (16-150 Hz)

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

The unit acts as a physical conduit for LocalBus data frames and 12 VDC auxiliary bus power while providing high noise attenuation between right-side expansion carriers and primary controller nodes. High-density connector pins maintain differential pair balance to prevent cross-talk during rapid backplane scanning cycles. Furthermore, the physical separation preserves channel-to-channel isolation parameters throughout adjacent analog and HART loop I/O cards, preventing field wiring transients or ground loops from corrupting system data transport.

Frequently Asked Questions

Q: Does the KJ4001X1-NA1 require independent field power connections?

A: No, the extender routes power directly from the active LocalBus power supply rail at 12 VDC (8 A maximum limit) to the expansion carrier.

Q: Can this unit be replaced while the primary controller carrier remains powered?

A: Yes, engineers can insert or disengage the extender on live carrier backplanes, provided system ground continuity is maintained to prevent bus noise spikes.

Q: How does the IP20 enclosure rating affect panel layout requirements?

A: The IP20 housing requires installation within a protective NEMA 4X or IP54 control cabinet to shield internal contacts from direct dust ingress and condensation.

Field Installation Guidelines

Mount the module directly into the right-side extension slot of the main DeltaV carrier until the retention latches snap firmly into place. Connect the inter-carrier bus cable without exceeding the specified bend radius to prevent internal conductor strain. Maintain a minimum of 5 full threads engagement on all metal enclosure panel screws to establish robust chassis ground continuity. Route all field wiring at least 300 mm away from high-voltage AC lines to minimize electromagnetic interference across the extended LocalBus lines.

You may also like