{"product_id":"eddy-current-displacement-plc-module-epro-con021-pr6423-011-110-cn","title":"Eddy Current Displacement PLC Module EPRO CON021 PR6423\/011-110-CN","description":"\u003ch2\u003eEPRO CON021+PR6423\/011-110-CN PLC Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEPRO CON021+PR6423\/011-110-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021+PR6423\u003c\/strong\u003e PLC Processor Module, operates as a dedicated hardware component for radial and axial shaft displacement, position, eccentricity, and speed measurement within turbomachinery monitoring systems. Configured for non-contact measurement in hazardous industrial environments, the \u003cstrong\u003eEPRO CON021+PR6423\/011-110-CN\u003c\/strong\u003e (\u003cstrong\u003eCON021+PR6423\u003c\/strong\u003e PLC Processor Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6423\/011-110-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e120 g (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard compact converter footprint with 5 mm probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +100 deg C (Converter), -35 to +180 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven via supply voltage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e-23 V to -32 V DC (Output -4 V to -20 V) \/ -21 V to -32 V DC (Output -2 V to -18 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e1 to 24 mm depending on sensor type (~2.0 mm linear range for \/011-110 variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Air Gap\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic steel (42CrMo4 \/ AISI 4140)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 (Converter housing LMgSi alloy), IP66 (Stainless steel\/PEEK sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, ATEX, IECEx, CSA, CN local certification (Intrinsic Safety Ex ia IIC T6\/T4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTurbomachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer system utilizes advanced eddy-current probe scaling matrices tailored specifically for ferromagnetic steel targets. System loop diagnostics require rigid gap voltage validation (-10 VDC targets) to maintain the 0.5 mm initial air gap orientation within the linear measurement window. High-frequency response parameters across the 0 to 20,000 Hz spectrum enable the processing hardware to map complex rotor dynamics without signal attenuation. Active cross-talk suppression methodologies protect the high-sensitivity 8 V\/mm voltage transmission from localized inductive noise, ensuring intrinsically safe executions in environments categorized under Ex ia IIC requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the dynamic output ranges generated by the signal converter module?\u003c\/p\u003e\n\u003cp\u003eA: The converter converts probe impedance transitions into analog outputs spanning either -2 VDC to -18 VDC or -4 to -20 VDC depending on the specific supply voltage rail configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Can the sensor withstand corrosive elements and fluids found near high-speed machinery?\u003c\/p\u003e\n\u003cp\u003eA: The sensor housing is constructed from stainless steel paired with a PEEK tip, providing an IP66 physical ingress protection rating to resist industrial contaminants.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the converter housing using four M5x20 screws onto the specified enclosure backing panel. Engineers must align the 5 mm eddy current probe relative to a target material matching the calibrated 42CrMo4\/AISI 4140 ferromagnetic steel profile to prevent sensitivity deviation. Adjust the initial mechanical gap to 0.5 mm using a precision feeler gauge or by monitoring the electrical gap voltage output before tightening the mounting brackets. Route the PTFE-insulated armored probe cable through dedicated, grounded conduit networks separated from parallel high-voltage AC cabling arrays. Ensure all shield wires connect to the designated instrument earth terminal to suppress external electromagnetic interference across the 0 to 20,000 Hz measurement spectrum.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44434199806051,"sku":"CON021+PR6423\/011-110-CN","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/467._af6a266c-3759-4b90-941d-e9282df5914e.jpg?v=1785747297","url":"https:\/\/www.autocontrolglobal.com\/products\/eddy-current-displacement-plc-module-epro-con021-pr6423-011-110-cn","provider":"AutoControl Global","version":"1.0","type":"link"}