{"product_id":"eddy-current-displacement-system-emerson-epro-con021-pr6423-010-010","title":"Eddy Current Displacement System Emerson EPRO CON021+PR6423\/010-010","description":"\u003ch2\u003eEmerson CON021 + PR6423\/010-010 Eddy Current Monitoring System\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed shaft displacement and vibration measurement, the \u003cstrong\u003eEmerson CON021 + PR6423\/010-010\u003c\/strong\u003e (\u003cstrong\u003eCON021 + PR6423\/010-010\u003c\/strong\u003e Eddy Current System) provides direct physical and electrical execution of dynamic rotor position monitoring within TSI systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021 + PR6423\/010-010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e120 g (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePanel mount (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C (Converter); -35 deg C to +180 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0–500 μm (Dynamic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical monitoring and eddy-current probe scaling\u003c\/h3\u003e\n\u003cp\u003eThe CON021 signal converter interfaces with the PR6423 eddy-current probe to facilitate precise shaft displacement tracking. Operators must ensure accurate probe scaling during system calibration, as the 8 V\/mm sensitivity requires a nominal gap of 1.5 mm to maintain linear output. Validation of gap voltage targets, typically centered within the -4 VDC to -20 VDC range, is required to prevent sensor saturation or signal clipping. Furthermore, the system incorporates cross-talk suppression techniques during installation to minimize signal interference when multiple probes are mounted in close proximity on rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021 converter be hot-swapped while the machine is running?\u003c\/p\u003e\n\u003cp\u003eA: The CON021 converter allows for electrical replacement; however, ensure that the power supply is isolated and the signal loops are properly bypassed to avoid triggering false trip signals in the connected TSI or control system.\u003c\/p\u003e\n\u003cp\u003eQ: What impact does the 10 m cable length have on the measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eA: The PR6423\/010-010 probe system is calibrated for a specific cable length. Extending or shortening the integral cable will alter the impedance and frequency response, resulting in significant measurement errors. Calibration must be verified following any repair or modification to the cable assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Mounting\u003c\/strong\u003e: Install the PR6423 sensor using the M10 or 3\/8”-24 thread, ensuring the probe tip is perpendicular to the shaft surface. Verify the 1.5 mm nominal gap using a feeler gauge to ensure the output signal resides within the linear operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Route the 10 m coaxial probe cable through dedicated grounded conduits. Maintain separation from high-power AC lines to prevent induced electromagnetic noise, which can interfere with the high-speed (\u0026lt;15 μs rise time) signal output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Connect the converter housing to a clean instrument earth. Improper grounding of the converter chassis can result in increased noise floor and decreased signal-to-noise ratio in dynamic vibration measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Validation\u003c\/strong\u003e: Post-installation, perform a static gap voltage check using a digital multimeter. Confirm the voltage output corresponds to the calculated gap value based on the 8 V\/mm sensitivity before commencing machine rotation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44357207883875,"sku":"CON021+PR6423\/010-100","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/386._a69a5a7c-66a6-432a-9d30-0a34178e1871.jpg?v=1784018806","url":"https:\/\/www.autocontrolglobal.com\/products\/eddy-current-displacement-system-emerson-epro-con021-pr6423-010-010","provider":"AutoControl Global","version":"1.0","type":"link"}