Emerson 1B30023H01 Ovation I/O Bus Terminator Module
Manufacturer: Emerson
-
Part Number: 1B30023H01
Condition:New with Original Package
Product Type: Bus Terminator Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Emerson 1B30023H01 Ovation Series I/O Bus Terminator Module
The Emerson 1B30023H01, also cataloged as the 1B30023H01 I/O Bus Terminator Module, operates as a dedicated hardware component for preventing signal reflections and maintaining impedance matching within Ovation I/O Bus subsystems.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 1B30023H01 |
| Brand | Emerson |
| Origin | USA |
| Weight | 0.2 kg |
| Dimensions | 100 mm x 25 mm x 20 mm |
| Operating Temp | -20 deg C to +60 deg C (-4 deg F to +140 deg F) |
| Power Consumption | Passive termination (no active power draw) |
| Electrical Role | Passive bus termination |
| Voltage Rating | Compatible with standard Ovation 5 VDC and 24 VDC I/O bus signals |
| Installation Location | Physical end of local I/O bus segments |
| Mounting Style | Direct plug-in to rack backplane |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Certifications | CE, UL, RoHS compliant |
Channel-to-Channel Isolation and Bus Signal Integrity
To secure communication integrity along the high-speed local backplane, this module matches the characteristic impedance of the differential transmission line. By absorbing residual energy at the terminal node, the device suppresses signal reflections and high-frequency noise. This passive design minimizes wave distortion and differential signal degradation without introducing active thermal drift or requiring independent channel-to-channel isolation circuits.
Frequently Asked Questions
Q: Where exactly must the 1B30023H01 be installed on the Ovation bus?
A: Install this module exclusively into the physical terminal slot at the final end of an I/O bus segment. Placing the terminator at any other node will cause impedance mismatches and communication faults.
Q: Does this terminator module require a separate external power connection?
A: No. The module acts as a passive network, consisting of high-tolerance matching resistors. It draws no operating current from the backplane and does not require an external power supply.
Q: How does this module handle backplane voltage tolerances?
A: The design safely accommodates standard Ovation backplane signaling ranges, including 5 VDC logic networks and 24 VDC industrial control signals.
Field Installation Guidelines
- Insert the terminator module into the dedicated end slot of the I/O backplane, verifying that all physical pins mate evenly prior to locking.
- Confirm that only one terminator is installed per physical end-of-line segment to avoid over-terminating the transmission path.
- Keep communication cables separated from primary AC power distribution lines to prevent inductive noise injection into the terminated bus.
- Ground the rack housing and the backplane assembly to a central instrument ground bar to maintain an effective noise shield.