Emerson 1B30023H01 Ovation I/O Bus Terminator Module
Emerson 1B30023H01 Ovation I/O Bus Terminator Module
Emerson 1B30023H01 Ovation I/O Bus Terminator Module
/ 3

Emerson 1B30023H01 Ovation I/O Bus Terminator Module

  • Manufacturer: Emerson

  • Part Number: 1B30023H01

  • Condition:New with Original Package

  • Product Type: Bus Terminator Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson 1B30023H01 Ovation Series I/O Bus Terminator Module

The Emerson 1B30023H01, also cataloged as the 1B30023H01 I/O Bus Terminator Module, operates as a dedicated hardware component for preventing signal reflections and maintaining impedance matching within Ovation I/O Bus subsystems.

Hardware Specifications

Parameter Specification
Model 1B30023H01
Brand Emerson
Origin USA
Weight 0.2 kg
Dimensions 100 mm x 25 mm x 20 mm
Operating Temp -20 deg C to +60 deg C (-4 deg F to +140 deg F)
Power Consumption Passive termination (no active power draw)
Electrical Role Passive bus termination
Voltage Rating Compatible with standard Ovation 5 VDC and 24 VDC I/O bus signals
Installation Location Physical end of local I/O bus segments
Mounting Style Direct plug-in to rack backplane
Humidity Range 5% to 95% RH (non-condensing)
Certifications CE, UL, RoHS compliant

Channel-to-Channel Isolation and Bus Signal Integrity

To secure communication integrity along the high-speed local backplane, this module matches the characteristic impedance of the differential transmission line. By absorbing residual energy at the terminal node, the device suppresses signal reflections and high-frequency noise. This passive design minimizes wave distortion and differential signal degradation without introducing active thermal drift or requiring independent channel-to-channel isolation circuits.

Frequently Asked Questions

Q: Where exactly must the 1B30023H01 be installed on the Ovation bus?

A: Install this module exclusively into the physical terminal slot at the final end of an I/O bus segment. Placing the terminator at any other node will cause impedance mismatches and communication faults.

Q: Does this terminator module require a separate external power connection?

A: No. The module acts as a passive network, consisting of high-tolerance matching resistors. It draws no operating current from the backplane and does not require an external power supply.

Q: How does this module handle backplane voltage tolerances?

A: The design safely accommodates standard Ovation backplane signaling ranges, including 5 VDC logic networks and 24 VDC industrial control signals.

Field Installation Guidelines

  • Insert the terminator module into the dedicated end slot of the I/O backplane, verifying that all physical pins mate evenly prior to locking.
  • Confirm that only one terminator is installed per physical end-of-line segment to avoid over-terminating the transmission path.
  • Keep communication cables separated from primary AC power distribution lines to prevent inductive noise injection into the terminated bus.
  • Ground the rack housing and the backplane assembly to a central instrument ground bar to maintain an effective noise shield.