{"product_id":"emerson-1c31166g01-ovation-16-channel-analog-output-module","title":"Emerson 1C31166G01 Ovation 16-Channel Analog Output Module","description":"\u003ch2\u003eEmerson 1C31166G01 Ovation Series Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for delivering deterministic analog outputs to field devices in Ovation distributed control systems, the \u003cstrong\u003eEmerson 1C31166G01\u003c\/strong\u003e (\u003cstrong\u003e1C31166G01\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1C31166G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm x 32 mm x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowered via standard 24 VDC Ovation backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 isolated AO channels (arranged in 4 banks of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable 4-20 mA DC (default), 0-10 V DC, 0-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% full scale (4-20 mA), +\/-0.05% temperature drift (0-60 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms (setpoint change to 99% output); \u0026lt; 5 ms fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V DC channel-to-backplane, 500 V DC channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ohm maximum (4-20 mA), 1 kohm minimum (0-10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvation I\/O chassis (1U slot), tool-less latching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1, CSA C22.2 No. 61010-1, IEC 61131-3, CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and HART Loop Integrity\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes galvanic isolation rated at 1500 V DC channel-to-backplane and 500 V DC channel-to-channel to prevent ground loop propagation across the 16 output channels. This physical separation prevents noise coupling from adjacent actuators or drives, maintaining the integrity of the 4-20 mA HART loop protocol signals against high common-mode voltages present in noisy electrical environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1C31166G01 module support hot-swappable replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The physical mechanical interface allows tool-less latching and supports complete online hot-swapping. The module can be extracted and inserted without turning off power to the I\/O chassis or disrupting system operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What internal diagnostics are available for loop monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module features dedicated channel-level diagnostics that automatically trigger alarms on the host controller upon detection of an \"Output Fault\" or \"Open Load\" condition in the field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the output range configured for individual channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The software parameters in the Ovation engineering station allow configuration of each channel to operate on 4-20 mA DC, 0-20 mA DC, or 0-10 V DC voltage outputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module into a vacant 1U slot of the Ovation I\/O chassis, ensuring the tool-less latches fully engage to lock the hardware to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eRun individual channel wires through standard shielded twisted pairs (STP), and keep signal paths physically isolated from high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003eTerminate the outer shield of each output cable only at the cabinet ground bar, ensuring no ground loops are created through connection at the field device.\u003c\/li\u003e\n\u003cli\u003eVerify that the total loop resistance for each 4-20 mA channel does not exceed the maximum load rating of 250 ohms to prevent output signal clipping.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43745521401955,"sku":"1C31166G01","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/32_e12406ea-5e76-4971-97f2-bb44e66993c6.jpg?v=1758617447","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-1c31166g01-ovation-16-channel-analog-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}