{"product_id":"emerson-deltav-kj1501x1-bc-2sis-ve5008-carrier-datasheet-manual","title":"Emerson DeltaV  KJ1501X1-BC 2SIS VE5008 Carrier Datasheet \u0026 Manual","description":"\u003ch2\u003eEmerson KJ1501X1-BC2 DeltaV SIS Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ1501X1-BC2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE5008\u003c\/strong\u003e CSLS Baseplate \/ Carrier, operates as a dedicated hardware component for critical safety I\/O deployment within Emerson DeltaV SIS networks. The assembly provides structural and electrical backplane pathways to distribute 24 VDC bussed field power and LocalBus communication across Smart Logic Solvers and CHARMs modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ1501X1-BC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107 x 41 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA (LocalBus), 12 VDC at 300 mA (Bussed Field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Code\u003c\/td\u003e\n\u003ctd\u003eVE5008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P2186X042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCSLS Baseplate \/ Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV SIS (CHARMs subsystem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modules\u003c\/td\u003e\n\u003ctd\u003eCSLS + CHARMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution\u003c\/td\u003e\n\u003ctd\u003e24 VDC bussed field power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g, 11 ms half-sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm (2-13.2 Hz), 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, ATEX, IECEx, FM, UKEX (Zone 2 \/ Class I Div. 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe electrical backbone of the KJ1501X1-BC2 utilizes dedicated internal channel-to-channel isolation and segmentation principles to decouple local safety processing logic from raw field transients. By managing parallel power distribution lines and communication buses, the baseplate structure eliminates common-mode interference and cross-talk during rapid safety state transitions. This routing layout supports transparent 4-20 mA HART loop protocol pass-through signals between attached CHARMs devices and active Smart Logic Solvers under harsh electrical conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the baseplate support hot-swapping of modules without interrupting the entire carrier segment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, the backplane communication paths and power distribution contacts are engineered to permit live hot-swapping of individual CSLS and CHARM modules. Removing a single unit cuts power only to that specific node without compromising the operation or data continuity of adjacent slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is ground integrity maintained across the baseplate during a field short-circuit event?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The carrier features integrated structural ground paths that sink field-side transients directly to the DIN rail. This topology ensures that high-voltage spikes are dissipated before they can breach the 12 VDC LocalBus or corrupt the logical safety solver processing memory.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Assembly and Mounting:\u003c\/strong\u003e Securely mount the baseplate vertically onto a standard 35 mm metallic DIN rail. Ensure that the structural grounding clips on the rear of the carrier make positive, paint-free electrical contact with the rail to maintain its electrical noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Hookup:\u003c\/strong\u003e Connect the redundant 24 VDC field power sources to the designated terminals. Verify that all supply circuits comply with the 12 VDC LocalBus and 300 mA bussed field ratings to prevent overcurrent heating within the internal traces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enclosure Parameters:\u003c\/strong\u003e For installations in environments with ISA-S71.04 Class G3 airborne contaminant profiles, the carrier must be housed inside a sealed, purged control cabinet with climate control to protect exposed backplane mating pins from oxidation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Verification:\u003c\/strong\u003e Before attaching or removing any safety components from the baseplate in ATEX\/IECEx Zone 2 or Class I Division 2 locations, confirm that all power to the circuits has been fully isolated to eliminate the risk of arc generation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43840645693539,"sku":"VE4001S2B1=KJ3222X1-BA1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/149_00ebc9b0-698d-4d83-99b2-f2e48e6f4357.jpg?v=1763361444","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-deltav-kj1501x1-bc-2sis-ve5008-carrier-datasheet-manual","provider":"AutoControl Global","version":"1.0","type":"link"}