Emerson EPRO PR6423/010-010 10mm Eddy Current Probe & CON021
Emerson EPRO PR6423/010-010 10mm Eddy Current Probe & CON021
Emerson EPRO PR6423/010-010 10mm Eddy Current Probe & CON021
/ 3

Emerson EPRO PR6423/010-010 10mm Eddy Current Probe & CON021

  • Manufacturer: ABB

  • Part Number: CON021+PR6423/010-010

  • Condition:New with Original Package

  • Product Type: Proximity Sensors

  • Country of Origin: Sweden

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Emerson EPRO PR6423/010-010 Proximity System

The Emerson EPRO PR6423/010-010, also cataloged as the 10 mm Eddy-Current Probe and CON021 Converter Assembly, operates as a dedicated hardware component for high-precision turbomachinery vibration and shaft position monitoring.

Hardware Specifications

Parameter Specification
Model PR6423/010-010
Brand Emerson EPRO
Origin Germany
Weight 0.8 kg
Dimensions 10 mm tip diameter / 10 m cable
Operating Temp -35 deg C to +180 deg C (Probe)
Power Consumption 24 VDC supply
Measurement Range 2 mm

Emerson EPRO TSI Characteristics

The PR6423/010-010 system utilizes high-resolution eddy-current probe scaling to convert non-contact shaft displacements into measurable electrical outputs. The CON021 signal converter executes gap voltage validation, maintaining a -10 VDC baseline for accurate rotor dynamics interpretation. System reliability is further supported by proactive cross-talk suppression, which mitigates signal noise when multiple probes are clustered around a single bearing housing. The CON021 module ensures I/O density scaling via 4-20 mA outputs, enabling direct integration into existing PLC and DCS infrastructure without additional signal conversion overhead. Galvanic isolation between the input and output stages provides effective protection against electrical transients, maintaining measurement integrity in demanding industrial environments.

Frequently Asked Questions

Q: How does the 10-meter cable length affect the system's calibration?

A: The system is factory-calibrated for the specified 10-meter cable impedance; therefore, any modifications to cable length must be followed by a system recalibration to prevent phase shift errors or signal attenuation.

Q: Is the CON021 unit field-configurable for different output ranges?

A: The CON021 is designed for standard 4-20 mA output ranges; however, internal diagnostic relay thresholds for "OK/Fault" status can be monitored by the host PLC to trigger alarms based on predefined setpoints.

Field Installation Guidelines

  1. Gap Setting: Establish the sensor gap using a feeler gauge based on the specific mechanical requirements of the rotating machine (typically targeting the center of the 0.25–2.25 mm linear range). Verify the resulting gap voltage corresponds to the -10 VDC nominal target.
  2. Mounting: Thread the probe into the mounting bracket or machine casing. Secure the assembly using the provided lock nuts to ensure the probe remains stationary despite high-frequency vibration during machine operation.
  3. Cabling: Manage the 10-meter integral cable with care, ensuring the minimum bend radius is maintained to prevent insulation stress. Route the cable through grounded metallic conduit to suppress ambient electromagnetic interference.
  4. Validation: After connection, apply 24 VDC power to the CON021. Confirm the "Sensor OK" relay is energized; a loss of this signal indicates either a disconnected cable, a gap outside the linear measurement range, or a probe tip collision.