{"product_id":"emerson-kj4001x1-nb1-12p3368x012-deltav-dual-left-side-extender","title":"Emerson KJ4001X1-NB1 12P3368X012 DeltaV Dual Left Side Extender","description":"\u003ch2\u003eEmerson KJ4001X1-NB1 DeltaV Extender Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ4001X1-NB1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ4001X1-NB1\u003c\/strong\u003e Dual Left-Side Extender, operates as a dedicated hardware component for carrier extension and communication continuity within Emerson DeltaV DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4001X1-NB1 12P3368X012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107 x 41 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCarrier-supplied backplane power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLeft-side carrier extension and signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, ATEX, IECEx (Zone 2, Class I Div. 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Signal Continuity \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe dual left-side extender establishes direct bus physical coupling between adjacent DeltaV expansion carriers while maintaining high noise immunity across high-speed system interconnects. High-density edge connectors preserve differential signal integrity and minimize cross-talk interference during parallel backplane data transport. Integrated channel-to-channel isolation barriers prevent localized ground loops and electrical transients from propagating back to primary controller nodes, guaranteeing deterministic communication timing across expanded I\/O banks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does inserting or removing the extender require complete system power isolation?\u003c\/p\u003e\n\u003cp\u003eA: No, engineers can seat or disengage the extender on an energized backplane carrier, provided hot-swap procedural steps are followed to prevent transient signal disruption on active control loops.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module maintain communication integrity across expanded carrier rows?\u003c\/p\u003e\n\u003cp\u003eA: Internal matched-impedance bus lines minimize signal reflection and transmission attenuation, retaining high data throughput speeds across multi-carrier topologies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlign the extender guide pins directly with the left-side carrier receptacle slot before applying firm horizontal force to fully seat the backplane interface connectors. Secure all mechanical retention screws to maintain ground continuity across the carrier frame. When routing interconnect cables near field wiring, enforce a minimum clearance of 300 mm from high-voltage AC lines. Connect local shield drains directly to the system grounding bar to maintain ATEX\/IECEx Zone 2 compliance.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43840365166691,"sku":"KJ4001X1-NB1 12P3368X012","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/112.2_d125ba4b-fa2b-4905-9314-af9a5478d03e.jpg?v=1763341220","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-kj4001x1-nb1-12p3368x012-deltav-dual-left-side-extender","provider":"AutoControl Global","version":"1.0","type":"link"}