{"product_id":"emerson-kj4005x1-ba1-deltav-controller-power-carrier","title":"Emerson KJ4005X1-BA1 DeltaV Controller \u0026 Power Carrier","description":"\u003ch2\u003eEmerson KJ4005X1-BA1 DeltaV Controller Carrier\u003c\/h2\u003e\n\u003cp\u003eConfigured for power distribution and backplane interconnectivity in Emerson DeltaV DCS platforms, the \u003cstrong\u003eEmerson KJ4005X1-BA1\u003c\/strong\u003e (\u003cstrong\u003eKJ4005X1-BA1\u003c\/strong\u003e Controller \u0026amp; Power Carrier) provides direct physical\/electrical execution. The 2-wide base hardware mounts system power supplies and controllers, routing 12 VDC LocalBus communication signals and power connections across integrated backplane traces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ4005X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e330 x 140 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e2-Wide Controller\/Power Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV S-Series DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Rating\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power Rating\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Resistance\u003c\/td\u003e\n\u003ctd\u003eShock: 10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection \u0026amp; Contaminants\u003c\/td\u003e\n\u003ctd\u003eIP20, ISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, ATEX, IECEx (Zone 2 \/ Class I Div 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Backplane and Galvanic Loop Integration\u003c\/h3\u003e\n\u003cp\u003eThe KJ4005X1-BA1 provides the primary backplane backbone required to route 4-20 mA HART loop protocol signals and high-density subsystem data across adjacent I\/O modules. Integrated power distribution traces deliver stable DC voltage to mounted controllers and supply channels, maintaining channel-to-channel isolation parameters to prevent common-mode noise transfer across process control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the KJ4005X1-BA1 carrier support live swapping of installed controllers or power modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The integrated backplane architecture supports hot-swapping connected DeltaV controllers and power supply units under live system power without disrupting ongoing LocalBus communications.\u003c\/p\u003e\n\u003cp\u003eQ: How is field circuit power physically isolated across the backplane?\u003c\/p\u003e\n\u003cp\u003eA: Power traces on the carrier split 24 VDC input into dedicated local bus circuits (12 VDC at 150 mA), bussed field power (12 VDC at 300 mA), and auxiliary field power (24 VDC at 32 mA) to suppress cross-channel noise coupling.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting hardware is required for Zone 2 installation?\u003c\/p\u003e\n\u003cp\u003eA: The carrier clips onto standard DIN rail profiles inside an IP54 or higher protective enclosure, complying with ATEX and IECEx Zone 2 \/ Class I Div 2 hazardous location rules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the KJ4005X1-BA1 carrier onto a standard DIN rail inside a sealed enclosure meeting local hazardous location specifications. Connect primary 24 VDC power feeds to the carrier terminal block using wire sizes rated for maximum system current draw. Ground the carrier frame directly to the central cabinet earth bar using low-impedance copper conductors to safeguard against electrostatic discharge and electromagnetic interference. Verify that air circulation within the cabinet maintains environmental conditions between -40 to +70 deg C before energizing the subsystem.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43840696680547,"sku":"KJ3102X032 12P1863X032","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/140_429ee5d6-c714-43ce-891a-2e1e3278b760.jpg?v=1763366702","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-kj4005x1-ba1-deltav-controller-power-carrier","provider":"AutoControl Global","version":"1.0","type":"link"}