Emerson KL4501X1-BB1 DeltaV CHARM Address Plug Position 2
Manufacturer: GE Fanuc
-
Part Number: KL4501X1-BB1
Condition:New with Original Package
Product Type: CHARM Address Plugs
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Emerson KL4501X1-BB1 DeltaV CHARM Address Plug
Configured for hardware slot addressing and physical module identification in Emerson DeltaV CHARM I/O platforms, the Emerson KL4501X1-BB1 (KL4501X1-BB1 Address Plug) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | KL4501X1-BB1 |
| Brand | Emerson |
| Origin | USA |
| Weight | 0.05 kg |
| Dimensions | 50 x 50 x 25 mm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | +6.3 VDC at 2 mA bus power rating |
| Address Position | #2 (Key position 1C) |
| System Compatibility | Emerson DeltaV CHARM I/O subsystem |
| Protection Class | IP20 |
| Airborne Contaminants | ISA-S71.04 Class G3 compliant |
| Humidity Range | 5% to 95% non-condensing |
| Shock Resistance | 10 g half-sine wave for 11 ms |
| Vibration Resistance | 1 mm P-P (2-13.2 Hz), 0.7 g (13.2-150 Hz) |
| Hazardous Certifications | ATEX, IECEx, FM, UKEX (Zone 2, Class I Div. 2) |
Channel-to-Channel Isolation & Backplane Signal Integrity
By enforcing fixed hardware addressing (Position #2) directly on the carrier baseplate, the KL4501X1-BB1 ensures deterministic routing of field data without software ID conflicts. This mechanical keying isolates the specific CHARM slot configuration, preserving strict channel-to-channel isolation parameters across the backplane wiring. Furthermore, accurate physical slot mapping is mandatory for integrating advanced loop diagnostics, maintaining seamless FOUNDATION Fieldbus and Profibus PA connectivity parameters through the primary DeltaV network controllers without cross-talk or node addressing errors.
Frequently Asked Questions
Q: Does the KL4501X1-BB1 plug support continuous hot-swapping procedures?
A: Yes, the address plug mounts passively on the carrier baseplate, allowing operators to safely remove or insert the associated CHARM module under live backplane power without interrupting adjacent channel execution.
Q: What limits the bus power consumption for this identification module?
A: The plug operates as a low-draw passive node on the carrier backplane, drawing a maximum of 2 mA from the standard +6.3 VDC supply rail, preventing localized voltage drops across fully populated I/O carriers.
Q: How does the module prevent incorrect slot placement?
A: The plug utilizes an integrated mechanical key (Position 1C) that physically rejects insertion attempts into incorrectly configured baseplate slots, enforcing strict I/O topography.
Field Installation Guidelines
Align the address plug's integrated mechanical key directly with the designated baseplate slot to prevent incorrect insertion. Press the plug firmly into the terminal block base until the physical locking detent snaps into position. Due to its IP20 rating, ensure the carrier assembly is installed within a NEMA 4X or IP54 rated control cabinet to protect the copper contacts from moisture condensation and industrial dust. Maintain a minimum clearance of 300 mm between the local I/O signal wiring trunk and any high-voltage AC conductors to prevent induced electromagnetic interference along the carrier backplane.