{"product_id":"emerson-kl4501x1-bb1-deltav-charm-address-plug-position-2","title":"Emerson KL4501X1-BB1 DeltaV CHARM Address Plug Position 2","description":"\u003ch2\u003eEmerson KL4501X1-BB1 DeltaV CHARM Address Plug\u003c\/h2\u003e\n\u003cp\u003eConfigured for hardware slot addressing and physical module identification in Emerson DeltaV CHARM I\/O platforms, the \u003cstrong\u003eEmerson KL4501X1-BB1\u003c\/strong\u003e (\u003cstrong\u003eKL4501X1-BB1\u003c\/strong\u003e Address Plug) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL4501X1-BB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 x 50 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+6.3 VDC at 2 mA bus power rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Position\u003c\/td\u003e\n\u003ctd\u003e#2 (Key position 1C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV CHARM I\/O subsystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (2-13.2 Hz), 0.7 g (13.2-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Certifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, FM, UKEX (Zone 2, Class I Div. 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Backplane Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eBy enforcing fixed hardware addressing (Position #2) directly on the carrier baseplate, the KL4501X1-BB1 ensures deterministic routing of field data without software ID conflicts. This mechanical keying isolates the specific CHARM slot configuration, preserving strict channel-to-channel isolation parameters across the backplane wiring. Furthermore, accurate physical slot mapping is mandatory for integrating advanced loop diagnostics, maintaining seamless FOUNDATION Fieldbus and Profibus PA connectivity parameters through the primary DeltaV network controllers without cross-talk or node addressing errors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the KL4501X1-BB1 plug support continuous hot-swapping procedures?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the address plug mounts passively on the carrier baseplate, allowing operators to safely remove or insert the associated CHARM module under live backplane power without interrupting adjacent channel execution.\u003c\/p\u003e\n\u003cp\u003eQ: What limits the bus power consumption for this identification module?\u003c\/p\u003e\n\u003cp\u003eA: The plug operates as a low-draw passive node on the carrier backplane, drawing a maximum of 2 mA from the standard +6.3 VDC supply rail, preventing localized voltage drops across fully populated I\/O carriers.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module prevent incorrect slot placement?\u003c\/p\u003e\n\u003cp\u003eA: The plug utilizes an integrated mechanical key (Position 1C) that physically rejects insertion attempts into incorrectly configured baseplate slots, enforcing strict I\/O topography.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlign the address plug's integrated mechanical key directly with the designated baseplate slot to prevent incorrect insertion. Press the plug firmly into the terminal block base until the physical locking detent snaps into position. Due to its IP20 rating, ensure the carrier assembly is installed within a NEMA 4X or IP54 rated control cabinet to protect the copper contacts from moisture condensation and industrial dust. Maintain a minimum clearance of 300 mm between the local I\/O signal wiring trunk and any high-voltage AC conductors to prevent induced electromagnetic interference along the carrier backplane.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43840395247715,"sku":"KL4501X1-BB1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/116_799090d5-387a-4636-bc6d-38fbf1e5478b.jpg?v=1763342597","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-kl4501x1-bb1-deltav-charm-address-plug-position-2","provider":"AutoControl Global","version":"1.0","type":"link"}