Emerson Ovation 5X00106G02 HART Analog Input Module
Manufacturer: Emerson
-
Part Number: 5X00106G02
Condition:New with Original Package
Product Type: Analog Input Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Emerson 5X00106G02 Ovation Series Intelligent Analog Input Module
Configured for acquiring 4-20 mA signals with HART protocol overlay in Ovation DCS networks, the Emerson 5X00106G02 (5X00106G02 Intelligent Analog Input Module) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 5X00106G02 |
| Brand | Emerson |
| Origin | USA |
| Weight | 0.35 kg |
| Dimensions | Standard Ovation I/O Chassis Form Factor |
| Operating Temp | -40 deg C to +70 deg C (-40 deg F to +158 deg F) |
| Power Consumption | Powered via standard 24 VDC Ovation I/O backplane |
| Input Channels | 8 analog input channels |
| Signal Type | 4-20 mA current loop with HART protocol overlay |
| Resolution | 16-bit analog-to-digital conversion |
| Accuracy | +/-0.1% of full scale |
| Software Integration | AMS Device Manager compatibility |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Certifications | CE, UL, RoHS compliant |
HART Loop Integration and Channel Isolation
The module demodulates the digital Highway Addressable Remote Transducer (HART) signal superimposed on the 4-20 mA analog current loop, enabling concurrent transmission of primary process variables and secondary diagnostic parameters. To maintain transmission fidelity, galvanic channel-to-channel isolation prevents ground loop currents from introducing offset errors into the 16-bit analog-to-digital converters. This architectural isolation secures the signaling paths when connected to multi-point field transmitters, suppressing common-mode electrical noise across all active ports.
Frequently Asked Questions
Q: Does the 5X00106G02 support online hot-swapping?
A: Yes. The module is configured for hot-swap operations within the Ovation I/O chassis. It can be inserted or extracted under power without disrupting backplane communications or the functionality of neighboring I/O modules.
Q: How does the module interface with HART diagnostics and asset management systems?
A: The module extracts secondary and tertiary HART variables from field transmitters and routes this digital data through the controller interface to the AMS Device Manager. This path supports online diagnostic sweeps, remote calibration, and parameterization of connected field instruments.
Field Installation Guidelines
- Align the module correctly with the guide rails of the Ovation I/O chassis slot before applying pressure to seat the backplane connectors.
- Terminate all field loops using shielded twisted pair (STP) wiring to mitigate external electromagnetic and radio-frequency interference.
- Connect the cable shields exclusively to the single-point instrument ground bar in the marshalling cabinet to avoid creating ground loops.
- Maintain the operating environment within the rated -40 deg C to +70 deg C range, ensuring adequate cabinet ventilation and airflow across the chassis.