{"product_id":"emerson-ovation-5x00106g02-hart-analog-input-module","title":"Emerson Ovation 5X00106G02 HART Analog Input Module","description":"\u003ch2\u003eEmerson 5X00106G02 Ovation Series Intelligent Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for acquiring 4-20 mA signals with HART protocol overlay in Ovation DCS networks, the \u003cstrong\u003eEmerson 5X00106G02\u003c\/strong\u003e (\u003cstrong\u003e5X00106G02\u003c\/strong\u003e Intelligent Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5X00106G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation I\/O Chassis Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C (-40 deg F to +158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowered via standard 24 VDC Ovation I\/O backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop with HART protocol overlay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAMS Device Manager compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHART Loop Integration and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module demodulates the digital Highway Addressable Remote Transducer (HART) signal superimposed on the 4-20 mA analog current loop, enabling concurrent transmission of primary process variables and secondary diagnostic parameters. To maintain transmission fidelity, galvanic channel-to-channel isolation prevents ground loop currents from introducing offset errors into the 16-bit analog-to-digital converters. This architectural isolation secures the signaling paths when connected to multi-point field transmitters, suppressing common-mode electrical noise across all active ports.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 5X00106G02 support online hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module is configured for hot-swap operations within the Ovation I\/O chassis. It can be inserted or extracted under power without disrupting backplane communications or the functionality of neighboring I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module interface with HART diagnostics and asset management systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module extracts secondary and tertiary HART variables from field transmitters and routes this digital data through the controller interface to the AMS Device Manager. This path supports online diagnostic sweeps, remote calibration, and parameterization of connected field instruments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module correctly with the guide rails of the Ovation I\/O chassis slot before applying pressure to seat the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eTerminate all field loops using shielded twisted pair (STP) wiring to mitigate external electromagnetic and radio-frequency interference.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shields exclusively to the single-point instrument ground bar in the marshalling cabinet to avoid creating ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain the operating environment within the rated -40 deg C to +70 deg C range, ensuring adequate cabinet ventilation and airflow across the chassis.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43745548206179,"sku":"5X00106G02","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/47_772e9fe8-d532-4ffa-9b19-df6a9aa35a2a.jpg?v=1758619399","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-ovation-5x00106g02-hart-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}