{"product_id":"emerson-ovation-5x00497g01-rev08-datasheet-technical-manual","title":"Emerson Ovation 5X00497G01 REV08 Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eEmerson 5X00497G01 REV08 Ovation Signal Conditioning Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson 5X00497G01 REV08\u003c\/strong\u003e serves as the primary \u003cstrong\u003e5X00497G01\u003c\/strong\u003e Signal Conditioning Module utilized to execute multi-signal conversion across Emerson Ovation Distributed Control System (DCS) platforms. This revision 08 hardware conditions, linearizes, and digitizes analog and digital execution vectors, routing mixed-signal processing tasks over a unified internal backplane data path.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00497G01 REV08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e135 mm x 105 mm x 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W typical, 5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eEmerson Ovation DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 configurable channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Typology\u003c\/td\u003e\n\u003ctd\u003eAI, AO, DI, DO, HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Conversion\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V DC channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eFOUNDATION Fieldbus, HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e10% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\/Hazardous Rating\u003c\/td\u003e\n\u003ctd\u003eSIL3 (IEC 61508), ATEX Zone 1, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrument Integration\u003c\/h3\u003e\n\u003cp\u003eThe module implements 1500 V DC channel-to-channel isolation networks to decouple every signal path from adjacent wiring paths and internal backplane logic. When field channels are configured to process the 4-20 mA HART loop protocol layer or interface with FOUNDATION Fieldbus segments, the integrated 16-bit converters filter out high-frequency electrical transients and common-mode noise voltages. This hardware design maintains analog-to-digital measurement accuracy within a +\/-0.05% full-scale boundary limit under high electromagnetic interference conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the mixed-signal logic configured on individual channels of the 5X00497G01 REV08?\u003c\/p\u003e\n\u003cp\u003eA: The configuration of the eight channels for analog or digital execution (AI, AO, DI, DO) is controlled via Ovation software tools. Internal electronic switches modify the termination impedance and signal pathways within the conditioning matrix based on the downloaded system database parameters.\u003c\/p\u003e\n\u003cp\u003eQ: What are the restrictions regarding the SIL3 certification during active operations?\u003c\/p\u003e\n\u003cp\u003eA: The hardware achieves functional compliance with SIL3 parameters according to IEC 61508 protocols. To maintain this hardware classification during maintenance states, internal diagnostic routines continuously report failure fractions to the Ovation controller over the backplane bus, ensuring fail-safe state execution bounds are preserved.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Earth and Carrier Grounding\u003c\/strong\u003e: Mount the module assembly firmly into its assigned slot on the Ovation I\/O carrier. Connect the integrated chassis ground rail directly to the plant copper instrument ground grid using an unpainted, low-impedance conductor maintaining a resistance parameter under 1 Ohm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Zone 1 Enclosure Requirements\u003c\/strong\u003e: For installations deployed within certified ATEX Zone 1 hazardous areas, the module must be mounted inside a purged or intrinsically safe industrial enclosure with a protection rating of at least IP54. Field terminals must not be worked on while the 24 VDC supply line is active.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding and Isolation\u003c\/strong\u003e: Terminate the cable drain wires from field instruments at the marshaling side terminal earth bar only. Do not ground the shielding at the sensor housing to prevent earth loop currents from distorting the 16-bit analog sampling logic.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43828632551523,"sku":"5X00497G01 REV08","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/47_4c1deec0-3c02-49e7-add3-73215a346a8d.jpg?v=1762757072","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-ovation-5x00497g01-rev08-datasheet-technical-manual","provider":"AutoControl Global","version":"1.0","type":"link"}