{"product_id":"emerson-ve4003s2b3-kj4001x1-cc1-deltav-dcs-analog-output-card","title":"Emerson VE4003S2B3 KJ4001X1-CC1 DeltaV DCS Analog Output Card","description":"\u003ch2\u003eEmerson VE4003S2B3 DeltaV Analog Output Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE4003S2B3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE4003S2B3 KJ4001X1-CC1\u003c\/strong\u003e Analog Output Card, operates as a dedicated hardware component for 4-20 mA analog signal execution within Emerson DeltaV DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4003S2B3 KJ4001X1-CC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107 x 41 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e10 g half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Approvals\u003c\/td\u003e\n\u003ctd\u003eZone 2, Class I Div. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module generates eight isolated 4-20 mA analog output loops to drive final control elements such as control valves and actuators. Galvanic channel-to-channel isolation prevents field ground loops and electrical noise from interfering with backplane signal processing. Integrated digital-to-analog converters deliver accurate current loop regulation across operating temperature variations. Furthermore, the hardware maintains continuous loop diagnostics, enabling real-time detection of open-circuit conditions and field wiring degradation while supporting HART loop communication transparency across DeltaV DCS networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support online hot-swapping during active DCS operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, operators can replace the module on an energized DeltaV I\/O carrier without isolating system power or interrupting adjacent channel communications.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation protect control loop signal integrity?\u003c\/p\u003e\n\u003cp\u003eA: Internal galvanic barriers isolate each output channel electrically, preventing field voltage spikes or wiring short circuits on one loop from damaging neighboring channels or backplane electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the card vertically into the designated DeltaV carrier slot until the locking retention lever fully locks into position. Connect field output cables to the terminal block using twisted-shielded pairs, grounding individual drain wires at the main cabinet earth bar only. Verify that all conduit entries maintain a minimum of 5 full threads engagement to satisfy Class I Div. 2 hazardous area requirements. Keep low-voltage 4-20 mA output wiring isolated from high-voltage AC power lines to avoid induced noise coupling.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43840375783523,"sku":"VE4003S2B3 KJ4001X1-CC1","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/107.2_823b5d48-d9d6-4943-89f9-273ea5426d4b.jpg?v=1763341881","url":"https:\/\/www.autocontrolglobal.com\/products\/emerson-ve4003s2b3-kj4001x1-cc1-deltav-dcs-analog-output-card","provider":"AutoControl Global","version":"1.0","type":"link"}