{"product_id":"epro-con021-pr6423-012-010-eddy-current-displacement-sensor-module","title":"EPRO CON021 PR6423\/012-010 Eddy Current Displacement Sensor Module","description":"\u003ch2\u003eEPRO CON021+PR6423\/012-010 Eddy Current Displacement Measurement System\u003c\/h2\u003e\n\u003cp\u003eConfigured for shaft displacement monitoring in hazardous industrial environments, the \u003cstrong\u003eEPRO CON021+PR6423\/012-010\u003c\/strong\u003e (\u003cstrong\u003eCON021+PR6423\u003c\/strong\u003e PLC Processor Module) provides direct physical\/electrical execution. The \u003cstrong\u003eEPRO CON021+PR6423\/012-010\u003c\/strong\u003e operates as a dedicated hardware component for precise non-contact measurement of shaft vibration, displacement, eccentricity, and speed within turbomachinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021 + PR6423\/012-010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e120 g (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact standard footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +180 deg C (Sensor) \/ -30 to +100 deg C (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDriven by supply voltage -21 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e5 mm eddy current probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e~2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Air Gap\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.015 mm deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003e-2 to -18 VDC or -4 to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66 (Sensor) \/ IP20 (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T6\/T4 Gb certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTurbomachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer system utilizes advanced eddy-current probe scaling matrices tailored specifically for ferromagnetic steel targets. System loop diagnostics require rigid gap voltage validation (-10 VDC targets) to maintain the 0.5 mm initial air gap orientation within the linear measurement window. High-frequency response parameters across the 0 to 20,000 Hz spectrum enable the processing hardware to map complex rotor dynamics without signal attenuation. Active cross-talk suppression methodologies protect the high-sensitivity 8 V\/mm voltage transmission from localized inductive noise, ensuring intrinsically safe executions in environments categorized under Ex ia IIC requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the dynamic output ranges generated by the signal converter module?\u003c\/p\u003e\n\u003cp\u003eA: The converter converts probe impedance transitions into analog outputs spanning either -2 VDC to -18 VDC or -4 to -20 VDC depending on the specific supply voltage rail configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Can the sensor withstand corrosive elements and fluids found near high-speed machinery?\u003c\/p\u003e\n\u003cp\u003eA: The sensor housing is constructed from stainless steel paired with a PEEK tip, providing an IP66 physical ingress protection rating to resist industrial contaminants.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the probe mechanically into the machine case using thread engagement metrics that prevent shifting under high physical vibration. Verify the target material matches the calibrated ferromagnetic steel (42CrMo4 \/ AISI 4140) specifications to maintain accurate 8 V\/mm scaling limits. Adjust the probe depth until a digital multimeter registers the target gap voltage baseline before locking the exterior jam nuts. Run the PTFE insulated armored cables inside dedicated conduit tracks separate from standard high-voltage AC lines to minimize ambient electronic interference. Ensure the signal converter housing is securely grounded to the local instrument earth plate within the local enclosure to preserve loop isolation.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":44434194694243,"sku":"CON021+PR6423\/012-010","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/466._03d53c0c-9eab-41eb-937f-8280fb650623.jpg?v=1785746661","url":"https:\/\/www.autocontrolglobal.com\/products\/epro-con021-pr6423-012-010-eddy-current-displacement-sensor-module","provider":"AutoControl Global","version":"1.0","type":"link"}