{"product_id":"ex5-02-11-19183-038-hima-h4007-safety-amplifier","title":"EX5 02 11 19183 038 HIMA H4007 Safety Amplifier","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA H4007 functions as a high-integrity, safety-related switching amplifier and intrinsic safety barrier engineered for hazardous, mission-critical industrial manufacturing spaces. This robust terminal-case module manages and isolates discrete digital field signals traveling between classified explosive environments and non-hazardous control room environments. Process automation engineers deploy this amplifier to interface safely with proximity sensors, pressure switches, emergency stop buttons, and valve position feedback sensors installed inside hazardous gas or dust zones.\u003c\/p\u003e\n\u003cp\u003eThe internal electronic architecture establishes a dependable energy-limiting barrier that prevents incendiary voltage spikes or thermal energy from crossing into explosive atmospheres. The device maintains full hardware compatibility with legacy and current HIMA control systems, allowing smooth integration into centralized safety shutdown loops without signal propagation delays.\u003c\/p\u003e\n\u003cp\u003eWe distribute this safety-critical instrumentation component exclusively in \u003cstrong\u003e100% brand new, original, and factory-sealed\u003c\/strong\u003e condition. This strict packaging standard guarantees uncompromised internal isolation transformers, untouched internal circuit traces, and total compliance with certified hazardous-area explosion ratings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the precise electrical, data transmission, mechanical, and safety certification parameters for the HIMA H4007 amplifier module. All values conform strictly to standard ASCII formatting.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eHIMA Paul Hildebrandt GmbH (Germany)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eModel Number\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eH4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eFactory Part Numbers\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eEX5 02 11 19183 038 \/ EX8 02 11 19183 039\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eModule Functional Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eSafety-Related Switching Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eEnclosure Case Design\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eRugged terminal case construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eCore Operational Principle\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eHandling and isolation of discrete digital field signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOutput Protection Mechanism\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eIntrinsically safe (Ex)i isolated output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eOutput Transmission Rating\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eFunctional Safety Threshold\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eSIL 3 \/ Category 4 compliant according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eExplosion Protection Standards\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eATEX \/ IECEx certified, protection type [Ex ib]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eSafety PLC System Compatibility\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eH41q, H51q, HIQuad, and HIMatrix controller platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eNominal Operating Voltage Input\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e220 V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eMaximum Output Frequency Limit\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eUp to 350 kHz processing throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eRedundancy Architecture Options\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eSupports high-availability 1oo2D and 2oo4D configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eMechanical Mounting Formats\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eStandard 35mm DIN Rail or Dedicated Subrack Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eAmbient Operational Temperature\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e-20 to +60 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003ePermissible Warehousing Temperature\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e-40 to +85 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eNet Component Hardware Weight\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e1.2 kg (2.64 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified [Ex ib] Hazardous Area Protection:\u003c\/strong\u003e The amplifier complies fully with strict ATEX and IECEx intrinsic safety standards. By restricting the total electrical energy routed to the field loop, the module eliminates the risk of sparking or thermal ignition, permitting safe sensor operation within gas and dust hazard zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Redundant Architecture Layouts:\u003c\/strong\u003e The internal safety logic integrates easily into high-availability 1oo2D and 2oo4D voter configurations. This architectural flexibility allows engineers to build redundant protection networks that maximize plant safety thresholds while minimizing costly nuisance shutdowns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Processing Output:\u003c\/strong\u003e Supporting processing frequencies up to 350 kHz, the solid-state circuitry tracks rapid changes in binary states effortlessly. This ultra-fast response profile ensures instantaneous signal updating for time-sensitive emergency shutdown (ESD) networks and turbine control schemes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Utility-Grade Isolation Barrier:\u003c\/strong\u003e The robust terminal-case enclosure handles environmental and electrical stress smoothly, operating across a wide temperature window from -20 to +60 degrees Celsius. Internal galvanic separation blocks heavy electrical noise, line surges, and harmonic interference, maintaining signal clarity between zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs the HIMA H4007 switching amplifier a brand new factory unit or refurbished surplus?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eWe distribute the HIMA H4007 amplifier module strictly as a 100% brand new, original, authentic factory-sealed unit. The product ships inside its original unopened manufacturer packaging with all factory safety seals intact, ensuring that the internal isolation electronics meet factory tolerances.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the difference between part numbers EX5 02 11 19183 038 and EX8 02 11 19183 039?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThese unique alphanumeric factory part numbers correspond to specific hardware sub-revisions, potting configurations, or regional certification marks assigned by HIMA during production. Both variants maintain core H4007 technical parameters, but you must check your existing panel drawings to match the exact hardware suffix.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this safety amplifier module require a separate external power supply for the field lines?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe H4007 connects to a nominal 220 V utility feed and converts this primary power internally to provide an intrinsically safe, isolated 24 VDC output loop for your hazardous-area field sensors, dropping the need for secondary external power supplies.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan I mount this module directly inside an unheated outdoor junction box?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe H4007 safely handles operational temperatures down to -20 degrees Celsius. While it handles standard industrial environments easily, installing the module within an outdoor cabinet located in a freezing climate requires an insulation kit or a small enclosure space heater to keep the ambient temperature above the -20 degrees Celsius threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43865604423779,"sku":"H4007","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/132_e3a24074-272f-442e-93af-dbc7f16d3334.jpg?v=1764568427","url":"https:\/\/www.autocontrolglobal.com\/products\/ex5-02-11-19183-038-hima-h4007-safety-amplifier","provider":"AutoControl Global","version":"1.0","type":"link"}