{"product_id":"experion-pks-analog-output-iota-honeywell-cc-taox01","title":"Experion PKS Analog Output IOTA | Honeywell CC-TAOX01","description":"\u003ch2\u003eHoneywell CC-TAOX01 Experion PKS Series C Analog Output IOTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAOX01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAOX01\u003c\/strong\u003e (Part Number 51308351-175) Analog Output Input\/Output Termination Assembly, operates as a dedicated hardware component for 16-channel analog current signal distribution and field wiring termination within Honeywell Experion PKS Series C distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX01 \/ 51308351-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.27 kg (0.60 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e22 to 28 VDC nominal supply loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA standard (0 mA, 2.9-21.1 mA settable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e800 ohm at 22-28 VDC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Voltage\u003c\/td\u003e\n\u003ctd\u003e16 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eCC-PAOX01, CC-PAOH01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineers integrate the assembly into distributed control loops requiring precise analog signal transmission and robust physical termination. The architecture processes standard 4-20 mA current loops while maintaining channel-to-channel isolation parameters to suppress common-mode voltage fluctuations and ground interference across connected actuators and valve positioners. Cold junction compensation and internal resistance regulation maintain output current linearity within 0.05% of full scale. The assembly provides open-circuit voltage handling up to 22 V and limits output ripple to under 100 mV peak-to-peak across a 250 ohm load.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the assembly support redundant configuration layouts?\u003c\/p\u003e\n\u003cp\u003eA: No, this specific hardware version is built as a non-redundant termination assembly designed for single-path Experion Series C I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: How does the assembly maintain output signal accuracy under varying thermal loads?\u003c\/p\u003e\n\u003cp\u003eA: Calibrated accuracy holds within 0.35% of full scale at 25 deg C, with an output temperature drift profile restricted to 0.005% of full scale per deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the assembly securely on standard DIN rail or panel plates inside a grounded industrial control enclosure. Maintain adequate vertical spacing above and below the unit to support natural thermal convection up to the 60 deg C operating ceiling. Connect field actuator wiring to the designated screw terminals, ensuring proper loop polarity for the 4-20 mA current signals. Terminate all shielded twisted-pair signal cables to a single earth ground bus bar at the cabinet entry point to prevent electromagnetic interference.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67741183082595,"sku":"CC-TAOX01","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/653..jpg?v=1792377129","url":"https:\/\/www.autocontrolglobal.com\/products\/experion-pks-analog-output-iota-honeywell-cc-taox01","provider":"AutoControl Global","version":"1.0","type":"link"}