Experion PKS C300 PROFIBUS-DP Gateway | Honeywell 8C-TP0XA1
Manufacturer: HONEYWELL
-
Part Number: 8C-TP0XA1
Condition:New with Original Package
Product Type: PROFIBUS-DP Gateway Modules
-
Country of Origin: Sweden
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Honeywell 8C-TP0XA1 PROFIBUS-DP Gateway Module
The Honeywell 8C-TP0XA1 serves as the primary 8C-TP0 PROFIBUS-DP Gateway Module utilized to execute deterministic data exchange across Experion PKS C300 platforms. Furthermore, it directly interfaces controllers with PROFIBUS DP field networks via physical RS-485 layers, subsequently executing transmission velocities up to 12 Mbps.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8C-TP0XA1 |
| Brand | Honeywell |
| Origin | N/A |
| Weight | 0.2 kg |
| Dimensions | 22 x 124 x 126 mm |
| Operating Temp | 0 deg C to +60 deg C |
| Storage Temp | -40 deg C to +85 deg C |
| Humidity | 5% - 95% non-condensing |
| Power Consumption | 430 mA at 24 VDC |
| System Compatibility | Experion PKS C300 |
| Communication Protocol | PROFIBUS DP (RS-485) |
| Max Transmission Rate | 12 Mbps |
| Interfaces | 1 x PROFIBUS DP 9-pin D-sub (optically isolated) |
| Network Connections | FTE A/B CAT5e, CAT5e redundancy sync |
| Redundancy Support | Yes |
| Certifications | UL, CE, RoHS |
Process Control & Network Integration Profiles
As a node within the DCS infrastructure, the module manages network requests while maintaining optical isolation across the RS-485 layer. Consequently, engineers can expand the architecture to integrate FOUNDATION Fieldbus / Profibus PA connectivity through downstream network links. Furthermore, integrated channel-to-channel isolation protocols prevent ground loops and electromagnetic interference (EMI) from disrupting the deterministic execution of standard control blocks within the primary C300 controller chassis.
Frequently Asked Questions
Q: What are the backplane current draw specifications for this module? A: The gateway module draws a maximum of 430 mA from the 24 VDC I/O chassis backplane supply during standard network operations.
Q: How does the module handle redundant controller synchronization? A: Redundancy synchronization executes via dedicated CAT5e sync connectors and FTE A/B CAT5e interfaces, thereby ensuring fault-tolerant switchover without interrupting the RS-485 transmission loop.
Q: Are the PROFIBUS DP interfaces physically isolated? A: Yes, the 9-pin D-sub PROFIBUS DP interface integrates optical isolation, which inherently mitigates transient voltages from field devices from propagating back to the logic processor.
Field Installation Guidelines
Installers must mount the gateway onto grounded DIN-rails within an environmentally controlled enclosure maintaining an ambient temperature of 0 deg C to +60 deg C. Subsequently, personnel must engage the 24 VDC chassis backplane connector, verifying that voltage drops remain within designated tolerance limits.
When terminating the PROFIBUS DP RS-485 network, technicians must utilize shielded twisted-pair cables terminated at the 9-pin D-sub port. Furthermore, the cable shield requires single-point grounding at the control cabinet to suppress noise. For redundant topologies, precisely route the CAT5e synchronization cables between the primary and secondary modules, thereby preventing physical tension or acute bend radii from degrading the network signal integrity.