{"product_id":"experion-pks-c300-profibus-dp-gateway-honeywell-8c-tp0xa1","title":"Experion PKS C300 PROFIBUS-DP Gateway | Honeywell 8C-TP0XA1","description":"\u003ch2\u003eHoneywell 8C-TP0XA1 PROFIBUS-DP Gateway Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TP0XA1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e8C-TP0\u003c\/strong\u003e PROFIBUS-DP Gateway Module utilized to execute deterministic data exchange across Experion PKS C300 platforms. Furthermore, it directly interfaces controllers with PROFIBUS DP field networks via physical RS-485 layers, subsequently executing transmission velocities up to 12 Mbps.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TP0XA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22 x 124 x 126 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% - 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e430 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP (RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e1 x PROFIBUS DP 9-pin D-sub (optically isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connections\u003c\/td\u003e\n\u003ctd\u003eFTE A\/B CAT5e, CAT5e redundancy sync\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Network Integration Profiles\u003c\/h3\u003e\n\u003cp\u003eAs a node within the DCS infrastructure, the module manages network requests while maintaining optical isolation across the RS-485 layer. Consequently, engineers can expand the architecture to integrate FOUNDATION Fieldbus \/ Profibus PA connectivity through downstream network links. Furthermore, integrated channel-to-channel isolation protocols prevent ground loops and electromagnetic interference (EMI) from disrupting the deterministic execution of standard control blocks within the primary C300 controller chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane current draw specifications for this module? A: The gateway module draws a maximum of 430 mA from the 24 VDC I\/O chassis backplane supply during standard network operations.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle redundant controller synchronization? A: Redundancy synchronization executes via dedicated CAT5e sync connectors and FTE A\/B CAT5e interfaces, thereby ensuring fault-tolerant switchover without interrupting the RS-485 transmission loop.\u003c\/p\u003e\n\u003cp\u003eQ: Are the PROFIBUS DP interfaces physically isolated? A: Yes, the 9-pin D-sub PROFIBUS DP interface integrates optical isolation, which inherently mitigates transient voltages from field devices from propagating back to the logic processor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstallers must mount the gateway onto grounded DIN-rails within an environmentally controlled enclosure maintaining an ambient temperature of 0 deg C to +60 deg C. Subsequently, personnel must engage the 24 VDC chassis backplane connector, verifying that voltage drops remain within designated tolerance limits.\u003c\/p\u003e\n\u003cp\u003eWhen terminating the PROFIBUS DP RS-485 network, technicians must utilize shielded twisted-pair cables terminated at the 9-pin D-sub port. Furthermore, the cable shield requires single-point grounding at the control cabinet to suppress noise. For redundant topologies, precisely route the CAT5e synchronization cables between the primary and secondary modules, thereby preventing physical tension or acute bend radii from degrading the network signal integrity.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":43866612105315,"sku":"8C-TP0XA1","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/214_618e4212-9c71-428c-a227-df8cd1101496.jpg?v=1764660906","url":"https:\/\/www.autocontrolglobal.com\/products\/experion-pks-c300-profibus-dp-gateway-honeywell-8c-tp0xa1","provider":"AutoControl Global","version":"1.0","type":"link"}