{"product_id":"experion-pks-controller-network-module-honeywell-cc-pcnt01","title":"Experion PKS Controller Network Module | Honeywell CC-PCNT01","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PCNT01 (Part No. 51405046-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary communication bridge for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This Network Interface Module manages high-speed data exchange between the central controller and various I\/O Link devices. It serves as a critical node in distributed control architectures, facilitating real-time monitoring and command execution. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring maximum uptime for your critical industrial processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-PCNT01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51405046-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS, C300 Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Link Interface \/ Network Gateway\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.311A @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInput Output Termination Assembly (IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED (Link, Health, Diagnostics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Network Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CC-PCNT01 utilizes proprietary Honeywell I\/O Link protocols to handle massive data packets without latency. This ensures the C300 controller receives field data in real-time, allowing for instantaneous logic adjustments in high-speed processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified IOTA Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module clicks directly onto the Input Output Termination Assembly (IOTA). This vertical mounting strategy eliminates complex inter-module wiring, reduces cabinet clutter, and accelerates the commissioning of new control segments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports redundant communication paths. In the event of a primary link failure, the system automatically switches to the backup path, preventing process trips and maintaining continuous data flow for safety-instrumented functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced On-Board Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated array of LED status indicators provides immediate visual feedback on module health and link activity. Technicians can identify network bottlenecks or hardware faults at a glance, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell builds the CC-PCNT01 to resist electromagnetic interference (EMI) and radio frequency interference (RFI). The vibration-resistant housing ensures stable operation in harsh environments, such as refinery floors or offshore platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CC-PCNT01 interface with the C300 controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-PCNT01 mounts onto a specific IOTA, which then connects to the C300 controller via the I\/O Link bus. It acts as the physical and logical translator between the controller's processing engine and the field-level I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a CC-PCNT01 module while the controller is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the hardware supports modular replacement, we recommend following Honeywell’s standard operating procedures for hot-swapping network modules to ensure the redundant link takes over correctly without disrupting the process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply is required for the CC-PCNT01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module operates on a standard 24 VDC supply with a nominal draw of 0.311A. Most Experion PKS system power supplies provide the necessary stable current via the IOTA backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit a refurbished or \"new surplus\" item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery CC-PCNT01 (51405046-175) we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e. Each module arrives in its original factory packaging with full traceability, guaranteeing it meets the latest industrial safety and performance standards.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43748879499363,"sku":"CC-PCNT01 51405046-175","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/203.1_f86c9367-44e3-43bd-b50e-be0e88b99378.jpg?v=1758878318","url":"https:\/\/www.autocontrolglobal.com\/products\/experion-pks-controller-network-module-honeywell-cc-pcnt01","provider":"AutoControl Global","version":"1.0","type":"link"}