{"product_id":"experion-pks-series-c-digital-input-modules-honeywell-8c-tdila1","title":"Experion PKS Series C Digital Input Modules | Honeywell 8C-TDILA1","description":"\u003ch2\u003eHoneywell 8C-TDILA1 Experion PKS Series C 32-Channel DI Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital signal acquisition from field devices in Experion PKS Series C control systems, the \u003cstrong\u003eHoneywell 8C-TDILA1\u003c\/strong\u003e (\u003cstrong\u003e8C-TDILA1\u003c\/strong\u003e Digital Input Modules) provides direct physical\/electrical execution. The hardware intercepts binary discrete states from physical plant equipment, executing signal conditioning and galvanic processing before transferring clean data packets across the system backbone for immediate process monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TDILA1 (51307141-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series C module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (18–30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDry contact \/ voltage input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL3 capable (IEC 61508\/61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in self-diagnostics and fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% - 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, TÜV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust channel-to-channel isolation circuits designed to suppress electrical cross-talk and prevent localized electrical faults from propagating across adjacent channels. Ground loop currents induced by field potential differentials are mitigated, maintaining signal fidelity under volatile electromagnetic interference conditions. This architecture provides steady protection for the internal microelectronics and ensures high system availability across the Experion PKS Series C architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 8C-TDILA1 handle safety-critical loops?\u003c\/p\u003e\n\u003cp\u003eA: The hardware is engineered with a SIL3-capable architecture according to IEC 61508\/61511 standards, making it certified for integration within dedicated safety instrumented systems.\u003c\/p\u003e\n\u003cp\u003eQ: What field wiring configurations are compatible with the 8C-TDILA1?\u003c\/p\u003e\n\u003cp\u003eA: The discrete input circuitry accommodates both unpowered dry contacts and active external voltage inputs operating within the nominal 24 VDC window.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped into a live system?\u003c\/p\u003e\n\u003cp\u003eA: Insertion and removal under power are supported when utilizing standard Series C baseplates, provided that strict plant-specific safety protocols for live-bus operations are maintained.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eGrounding Protocol: Ensure the Series C baseplate is bonded to the master instrument ground grid using low-impedance copper conductors to ensure proper shield termination and maximum surge immunity.\u003c\/li\u003e\n\u003cli\u003eField Wiring Separation: Segregate low-voltage DC input cables from high-voltage AC distribution lines inside the enclosure channels to prevent capacitive and inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003eThermal Management: Maintain clear clearance paths around the module assembly to allow natural convective heat dissipation, ensuring the ambient internal enclosure temperature remains below the 70 deg C threshold.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43869021044835,"sku":"8C-TDILA1 51307141-175","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/384_b390e80a-c381-463f-adfc-9d3ac24755a2.jpg?v=1764741788","url":"https:\/\/www.autocontrolglobal.com\/products\/experion-pks-series-c-digital-input-modules-honeywell-8c-tdila1","provider":"AutoControl Global","version":"1.0","type":"link"}