{"product_id":"experion-series-c-thermocouple-input-module-honeywell-cc-tcnt01","title":"Experion Series C Thermocouple Input Module | Honeywell CC-TCNT01","description":"\u003ch2\u003eHoneywell CC-TCNT01 Experion PKS Series C Thermocouple Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TCNT01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TCNT01\u003c\/strong\u003e (Part Number 51308307-175) Thermocouple Analog Input Module, operates as a dedicated hardware component for 16-channel millivolt signal conversion and temperature loop execution within Honeywell Experion PKS Series C systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TCNT01 \/ 51308301-175 \/ 51308307-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 145 mm x 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply (0.311 A current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated thermocouple channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouples\u003c\/td\u003e\n\u003ctd\u003eTypes J, K, T, E, R, S, B, N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eplus\/minus 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eG3 conformal-coated printed wiring assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSeries C I\/O rack \/ IOTA carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eEngineers integrate the input module into distributed control networks requiring precise millivolt-to-digital signal processing across severe thermal environments. Integrated automatic Cold Junction Compensation (CJC) located directly at the terminal connection point compensates for ambient temperature shifts inside the panel enclosure. Channel-to-channel galvanic isolation blocks high-voltage ground loops and suppresses electromagnetic noise in furnace and turbine processing loops. Internal diagnostic routines continuously evaluate sensor circuit impedance to flag open-circuit burnout states without tripping adjacent control channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TCNT01 handle raw millivolt signal inputs directly?\u003c\/p\u003e\n\u003cp\u003eA: Yes, in addition to standard IEC thermocouple curves, the analog front-end processes low-level millivolt signals directly from field transmitters.\u003c\/p\u003e\n\u003cp\u003eQ: How does the G3 conformal coating protect the assembly in industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: The G3-rated coating seals the printed wiring assembly against airborne corrosive agents such as hydrogen sulfide and chlorine gas under high ambient humidity conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module detect a broken sensor wire on a connected thermocouple loop?\u003c\/p\u003e\n\u003cp\u003eA: Yes, onboard diagnostics automatically execute open-circuit burnout detection to trigger pre-configured safety states and diagnostic alerts within the Experion software platform.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on the designated Series C carrier rack or IOTA frame inside a grounded control cabinet. Maintain a minimum vertical spacing of 50 mm above and below the module to promote free convection airflow up to the 70 deg C thermal threshold. Connect thermocouple Extension wires to the IOTA screw terminals, observing strict polarity for the specific thermocouple alloy type. Terminate all cable shields to a dedicated earth ground rail at the enclosure base to prevent common-mode voltage buildup.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44080526065763,"sku":"CC-TCNT01 51308307-175","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/381_35f17460-ef45-4a3f-bab9-c250cd22b290.jpg?v=1774495769","url":"https:\/\/www.autocontrolglobal.com\/products\/experion-series-c-thermocouple-input-module-honeywell-cc-tcnt01","provider":"AutoControl Global","version":"1.0","type":"link"}