{"product_id":"fc-sai-1620m-honeywell-sil3-safety-manager-input-card","title":"FC-SAI-1620M | Honeywell | SIL3 Safety Manager Input Card","description":"\u003ch2 class=\"cdk-visually-hidden ng-star-inserted\"\u003eGemini 说\u003c\/h2\u003e\n\u003cp\u003eHoneywell FC-SAI-1620M Safety Manager 16-Channel Analog Input Module\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SAI-1620M (Model: FC-SAI-1620M)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density safety analog input module specifically engineered for the Honeywell Safety Manager® and Experion® PKS Safety Instrumented System (SIS). This module provides 16 independent analog input channels, organized into two groups of eight, to facilitate high-fidelity acquisition of field signals from transmitters and sensors.\u003c\/p\u003e\n\u003cp\u003eDesigned for SIL3 safety-critical applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SAI-1620M (Part Number: FC-SAI-1620M)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles standard 4–20 mA current loops, typically converted to a 0–4 V range via a field termination assembly. It is certified for Class I, Division 2 hazardous locations, ensuring stable performance in demanding petrochemical, oil and gas, and power generation environments. With integrated galvanic isolation and advanced self-diagnostics, the module ensures maximum safety integrity and minimal downtime for industrial automation ecosystems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SAI-1620M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule adheres to the following engineering specifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell (USA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SAI-1620M\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Safety Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Honeywell Safety Manager, Experion PKS SIS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e: 16 Channels (Isolated in groups of 8)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e: 4–20 mA current loops (converted to 0–4 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e: 0–4 V DC (after field termination conversion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e: SIL3 compliant per IEC 61508\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e: ±0.1 % of full scale typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e: 12-bit to 16-bit high-precision conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Galvanic isolation between inputs and common system reference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e: 5 V DC and\/or 24 V DC supply (Approx. 35 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40 °C to +70 °C (-40 °F to +158 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e: Class I, Division 2 Hazardous Locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 2 cm × 19 cm × 12.8 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.14 kg (Module only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: CE, TÜV, UL, CSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44028289679459,"sku":"FC-SАI-1620М","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/116._adc677b1-0f38-400c-ae79-7788b8ebf5dc.jpg?v=1772181885","url":"https:\/\/www.autocontrolglobal.com\/products\/fc-sai-1620m-honeywell-sil3-safety-manager-input-card","provider":"AutoControl Global","version":"1.0","type":"link"}