{"product_id":"fc-tsgash-1624-honeywell-safety-manager-field-termination","title":"FC-TSGASH-1624 Honeywell | Safety Manager Field Termination","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-TSGASH-1624 (Model: FC-TSGASH-1624)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Field Termination Assembly (FTA) module engineered by Honeywell for use with the Safety Manager® and Experion® SIS (Safety Instrumented System) platforms.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module functions as the specialized physical interface between safety-critical field sensors—specifically gas and flame detectors—and high-density analog input modules like the SAI-1620m.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eDesigned to meet the rigorous demands of SIL-rated environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-TSGASH-1624 (Part Number: FC-TSGASH-1624)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential signal conditioning,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eimpedance matching,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand distribution for 16 independent analog channels.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt supports HART communication protocols,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling pass-through diagnostics and remote configuration of field instruments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEach channel is equipped with individual fuse protection to ensure that localized field faults do not compromise the integrity of the entire safety loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-TSGASH-1624\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis built to the following professional engineering standards:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturer\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell (USA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eFC-TSGASH-1624\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16-Channel Field Termination Assembly (FTA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Architecture\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell Safety Manager \/ Experion SIS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Channels\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16 Analog Inputs with a common 0V reference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Signal Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0–20 mA or 4–20 mA (supports up to 25 mA over-range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Resistance\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e500 Ω ± 5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Output\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0–4 V DC output to analog input module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMeasurement Accuracy\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e±0.\u003c\/span\u003e\u003cspan class=\"\"\u003e1% typical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Requirements\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eExternal 24 V DC nominal supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCircuit Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePer-channel 500 mA fuses (Schurter or equivalent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWiring Termination\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eScrew terminals supporting wire sizes up to 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm² (AWG 14)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Configuration\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDIN EN Rail (TS32 \/ TS35 × 7.\u003c\/span\u003e\u003cspan class=\"\"\u003e5)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e22.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm x 10.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 cm x 8.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm (Approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e225 x 70 x 60 mm card size)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWeight\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e52 kg (\u003c\/span\u003e\u003cspan class=\"\"\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e15 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCertifications\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCE,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTUV,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUL,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand CSA (Safety Rated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44028258451555,"sku":"FC-TSGASH-1624","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/153._af0d8543-4550-42a8-b631-84f68de30bf8.jpg?v=1772178017","url":"https:\/\/www.autocontrolglobal.com\/products\/fc-tsgash-1624-honeywell-safety-manager-field-termination","provider":"AutoControl Global","version":"1.0","type":"link"}