{"product_id":"foxboro-p0960ha-evo-gateway-processor-fbm-baseplate","title":"Foxboro P0960HA Evo Gateway Processor FBM Baseplate","description":"\u003ch2\u003eFoxboro P0960HA Gateway Processor \u0026amp; Redundant FBM Baseplate\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0960HA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0960HA\u003c\/strong\u003e Gateway Processor \u0026amp; Redundant FBM Baseplate, operates as a dedicated hardware component for regulated power distribution and backplane fieldbus interface management within Foxboro Evo and I\/A Series control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0960HA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63.5 x 124.46 x 307.34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Bus Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slots\u003c\/td\u003e\n\u003ctd\u003eDual slots for redundant module installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modules\u003c\/td\u003e\n\u003ctd\u003eFBM217, FBM218, FBM219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRedundant Module Fieldbus to System Backplane \/ GW30 Gateway Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe assembly establishes galvanic channel-to-system isolation barriers that segregate field instrument loop wiring from internal backplane processing logic and power distribution rails. Internal multi-layer circuit trace geometries maintain signal impedance levels, eliminating digital frequency shift keying (FSK) attenuation across 4-20 mA HART loop protocol passes. Dedicated internal bus trace routing separates primary and secondary module slots, suppressing cross-talk and preventing circulating earth ground currents across redundant fieldbus module pairs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing an individual Fieldbus Module on the P0960HA interrupt communication on the adjacent slot?\u003c\/p\u003e\n\u003cp\u003eA: No, individual baseplate slots feature isolated power routing and independent fieldbus bus interface connectors. Maintenance personnel can hot-swap a single module on one slot while the adjacent redundant module maintains live system backplane communication without disruption.\u003c\/p\u003e\n\u003cp\u003eQ: Can single non-redundant fieldbus modules operate on the P0960HA baseplate assembly?\u003c\/p\u003e\n\u003cp\u003eA: Yes, a single FBM functions correctly in either slot. However, complete fault-tolerant system execution requires populating both slots with a matched module pair.\u003c\/p\u003e\n\u003cp\u003eQ: What cabinet grounding configuration prevents loop ground interference from affecting baseplate communications?\u003c\/p\u003e\n\u003cp\u003eA: Connect a low-impedance copper ground strap directly from the baseplate grounding terminal to the main cabinet earth bus bar, while terminating field cable shields at a single dedicated ground point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the baseplate horizontally or vertically onto cabinet DIN rails or mounting sub-panels using dedicated mechanical fasteners.\u003c\/li\u003e\n\u003cli\u003eConnect primary DC power leads to the baseplate input terminal block, verifying correct polarity prior to energizing the bus rails.\u003c\/li\u003e\n\u003cli\u003eSecure a low-impedance copper grounding cable from the baseplate earth stud directly to the main enclosure instrument ground bar.\u003c\/li\u003e\n\u003cli\u003eAlign the fieldbus module rear connectors with slot track guides and press the module inward until side retaining clips engage securely.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage field signal cabling from high-voltage AC conductors inside cabinet wiring channels, landing shield wires at a single chassis ground bar.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43927816831075,"sku":"P0960HA","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/259_eecfd2df-1c9b-4d16-a365-ef5cfb57f064.jpg?v=1767150004","url":"https:\/\/www.autocontrolglobal.com\/products\/foxboro-p0960ha-evo-gateway-processor-fbm-baseplate","provider":"AutoControl Global","version":"1.0","type":"link"}