{"product_id":"foxboro-p0972ts-evo-redundant-fbm-mounting-baseplate","title":"Foxboro P0972TS Evo Redundant FBM Mounting Baseplate","description":"\u003ch2\u003eFoxboro P0972TS Redundant FBM Mounting Baseplate Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0972TS\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0972TS\u003c\/strong\u003e Redundant FBM Baseplate Assembly, operates as a dedicated hardware component for power distribution, signal routing, and backplane communication bus connectivity within Foxboro Evo and I\/A Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0972TS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e63.5 x 124.46 x 307.34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Bus Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slots\u003c\/td\u003e\n\u003ctd\u003eDual slots for redundant module installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modules\u003c\/td\u003e\n\u003ctd\u003eFBM217, FBM218, FBM219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRedundant Module Fieldbus to System Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe baseplate assembly establishes channel-to-system galvanic isolation barriers that separate field instrument wiring from the internal processing backplane and DC power rails. Internal copper bus traces maintain signal path geometry to prevent attenuation or noise coupling on 4-20 mA HART loop protocol communications. This circuit design limits cross-talk between adjacent slots, protects module internal logic from field transients, and guarantees uninterrupted fieldbus data transfers across redundant dual-module pairings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing a failed module on one slot disrupt communication or power on the adjacent slot?\u003c\/p\u003e\n\u003cp\u003eA: No, individual baseplate slots feature isolated power routing and independent fieldbus interface connectors. Maintenance engineers can hot-swap a single Fieldbus Module on one slot while the adjacent redundant module maintains active processing without disruption.\u003c\/p\u003e\n\u003cp\u003eQ: Can single non-redundant fieldbus modules be installed on the P0972TS baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, a single FBM functions correctly in one slot, but full fault-tolerant operation requires installing a matched module pair across both baseplate slots.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding procedure prevents ground loops from affecting module signals on the baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Installers must connect the baseplate ground stud directly to the main cabinet instrument ground bar using a low-impedance copper strap while grounding field cable shields at a single point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the baseplate horizontally or vertically onto standard cabinet mounting rails using dedicated mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect primary power distribution feeders to the baseplate power terminals, verifying correct polarity before applying power.\u003c\/li\u003e\n\u003cli\u003eSecure a low-impedance grounding strap between the baseplate grounding terminal and the central cabinet earth bus.\u003c\/li\u003e\n\u003cli\u003eAlign module rear connectors with slot guide tracks and seat each module firmly until retaining latches click into place.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage field signal cabling from high-voltage AC conductors inside wire ducts, terminating shield wires at a single enclosure earth point.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43927796842595,"sku":"P0972TS","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/180.1_f4221fd7-8113-4238-be26-6d495edf4937.jpg?v=1767148540","url":"https:\/\/www.autocontrolglobal.com\/products\/foxboro-p0972ts-evo-redundant-fbm-mounting-baseplate","provider":"AutoControl Global","version":"1.0","type":"link"}