{"product_id":"fs-tro-1024-honeywell-fsc-relay-output-assembly","title":"FS-TRO-1024 | Honeywell FSC Relay Output Assembly","description":"\u003ch2\u003eHoneywell FS-TRO-1024 Digital Output Relay Contact Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TRO-1024\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-TRO-1024\u003c\/strong\u003e Digital Output Relay Contact Field Termination Assembly, operates as a dedicated hardware component for relay-based signal switching within Honeywell FSC safety system networks. Configured for high-integrity load control in industrial control environments, this assembly routes controller output commands directly to external field actuators, solenoids, and alarm annunciators. The unit interfaces directly with redundant digital output modules via dedicated system interconnection cables, translating internal logic commands into physical relay contact states. Universal snap-in DIN rail mounting geometry allows efficient placement inside control cabinets. Standard screw terminal blocks facilitate robust field cable termination and loop distribution across process automation facilities.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TRO-1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e60 x 70 x 54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 25 mA (WDG input current: 4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e10 relay output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Specification\u003c\/td\u003e\n\u003ctd\u003eRelay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VAC \/ 36 VDC (IEC 61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e100 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eHoneywell 10208\/2\/1 digital output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnection Cable\u003c\/td\u003e\n\u003ctd\u003eSIC-C-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminals (up to 2.5 mm2 \/ AWG 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail (TS32 \/ TS35 x 7.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFunctional Safety \u0026amp; Relay Switching Integrity\u003c\/h3\u003e\n\u003cp\u003eSafety-instrumented systems (SIS) require robust isolation between low-voltage controller logic and higher-energy field loads. The FS-TRO-1024 provides 10 independent relay output channels designed to support high-reliability interlocking architectures. Each channel manages inductive and resistive loads up to 2 A, maintaining strict electrical isolation across channel boundaries to prevent cross-talk and transient feedback into the central processor backplane. The assembly incorporates fixed contact configurations compatible with redundant output module pairs, ensuring deterministic state execution during safety shutdown sequences. If a downstream fault occurs, the electromechanical separation protects internal control hardware from overvoltage surges and ground potential shifts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module interface with redundant digital output cards?\u003c\/p\u003e\n\u003cp\u003eA: The assembly connects directly to dual Honeywell 10208\/2\/1 digital output modules using the standardized SIC-C-12 system interconnection cable, maintaining redundant signal paths for high-availability safety applications.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum electrical ratings for the relay output contacts?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 10 relay channels supports a maximum switching voltage of 30 VAC \/ 36 VDC in compliance with IEC 61010-1 standards, with a maximum continuous current limit of 2 A and a load capacitance threshold of 100 nF.\u003c\/p\u003e\n\u003cp\u003eQ: Can maintenance personnel replace individual relay elements on the termination board?\u003c\/p\u003e\n\u003cp\u003eA: The field termination assembly functions as an integrated terminal unit; individual relays are not field-replaceable components. Replacement requires swapping the complete assembly unit following standard plant lockout\/tagout safety protocols.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the assembly securely onto a standard TS32 or TS35 x 7.5 mm DIN rail using the integrated snap-in mechanism, ensuring a minimum rail allocation of 61 mm. Secure end stoppers on both sides of the baseplate to prevent lateral shifting under high-vibration industrial conditions.\u003c\/p\u003e\n\u003cp\u003eRoute external field wiring through dedicated wire ducts, maintaining physical segregation between power distribution lines and low-voltage control signals. Strip conductor insulation to exactly 7 mm, insert the wire ends into the screw terminal blocks, and tighten each screw to a torque rating of 0.5 Nm. Ensure that wire gauges do not exceed 2.5 mm2 (AWG 14).\u003c\/p\u003e\n\u003cp\u003eVerify system grounding before attaching the SIC-C-12 interconnection cable from the Honeywell output module. Check that all field devices connected to the 10 relay channels operate within the specified 30 VAC \/ 36 VDC and 2 A limits prior to energizing the control system power supplies.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67740962717795,"sku":"FS-TRO-1024","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/188._d9d33633-24c9-43c1-bfa0-bd382b392402.jpg?v=1792371336","url":"https:\/\/www.autocontrolglobal.com\/products\/fs-tro-1024-honeywell-fsc-relay-output-assembly","provider":"AutoControl Global","version":"1.0","type":"link"}