Fuji Electric DCS NC1AX04-MR Voltage Current Input Unit
Fuji Electric DCS NC1AX04-MR Voltage Current Input Unit
Fuji Electric DCS NC1AX04-MR Voltage Current Input Unit
/ 3

Fuji Electric DCS NC1AX04-MR Voltage Current Input Unit

  • Manufacturer: Yokogawa

  • Part Number: NC1AX04-MR

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: Japan

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Fuji Electric NC1AX04-MR operates as a high-precision, rack-mounted 4-channel multi-range analog input module engineered exclusively for the MICREX-F F70 programmable logic controller (PLC) platform. This high-performance automation component interfaces directly with field sensors, temperature transmitters, and flow meters, converting raw variable electrical currents and voltages into stabilized 12-bit digital values. Control engineers deploy this module inside processing networks to capture rapid instrument changes, utilizing its flexible input ranges to manage diverse signal profiles on a single standardized hardware face.

Technical Specifications

Parameter Specification Value
Manufacturer Fuji Electric
Model Number NC1AX04-MR
Module Classification Multi-Range Analog Input Module
System Architecture Fuji MICREX-F / F70 PLC Infrastructure
Active Input Capacity 4 distinct analog input channels
Bipolar Voltage Ranges Plus/minus 10 V, plus/minus 5 V, plus/minus 1 V, plus/minus 0.5 V
Bipolar Current Ranges Plus/minus 20 mA, plus/minus 10 mA, plus/minus 2 mA, plus/minus 1 mA
A/D Processing Resolution 12-bit analog-to-digital converter matrix
Measurement Conversion Accuracy Plus/minus 0.1% of full scale span under typical loads
Voltage Input Impedance Greater than or equal to 1 Megohm
Current Input Impedance 250 Ohms standard internal resistance
Loop Conversion Speed 1 ms execution time per active channel
Electrical Circuit Isolation High-integrity channel-to-channel and channel-to-system isolation
Visual Diagnostic Display Integrated real-time LEDs tracking module and channel health
Ingress Enclosure Protection IP20
Physical Outer Profile 130 mm x 100 mm x 30 mm (W x H x D)
Net Hardware Weight 0.5 kg (1.10 lbs)
Installation Mounting Method Slots directly into standard MICREX-F backplane chassis
Thermal Operating Envelope 0 to +55 degrees Celsius
Storage Temperature Limits -20 to +70 degrees Celsius
Permissible Relative Humidity 5% to 95% relative humidity (non-condensing)
Global Industry Validations CE marked, UL listed, CSA approved
Engineering Country of Origin Japan
Procurement Status 100% Brand New and Original in Factory Packing

Engineering Advantages

Complete Channel-to-Channel Isolation Blocks Destructive Ground Loops

Unlike lower-tier shared-ground input cards, the NC1AX04-MR incorporates complete galvanic channel-to-channel and channel-to-system electrical isolation. Plant facilities often exhibit significant electrical ground potential differences between widely separated field instruments. This module isolates each input loop entirely, trapping stray common-mode voltages and preventing destructive ground currents from migrating between channels or entering the main MICREX-F backplane bus processor.

Multi-Range Signal Agility Eliminates Extra Hardware Inventory

The onboard input channels accommodate both voltage and current spans, supporting diverse sub-ranges from low-level plus/minus 0.5V transmitter steps up to standard plus/minus 20 mA industrial loops. This flexibility allows plant designers to land different signal types onto adjacent terminals of the same 0.5 kg module. By removing the need to source separate dedicated voltage and current cards, this universal profile lowers spare parts inventory overhead.

Sub-Millisecond Conversion Tracking Enhances Closed-Loop Accuracy

The high-speed A/D conversion circuit processes signal states at a rapid rate of 1 ms per channel. This quick performance ensures that real-time process deviations—such as rapid fluid pressure drops or sudden heat spikes—are written to the central F70 processor registers without communication lag. This responsive tracking allows the PLC safety routines and active PID blocks to respond fast, preserving tight control tolerances across delicate chemical, manufacturing, and power cycles.

FAQs

  • How do you configure individual channels on the NC1AX04-MR for voltage versus current modes?

    You select and configure the specific electrical input ranges for each channel via software within the standard Fuji Electric MICREX-F programming toolset. When setting up a channel for a current loop (such as plus/minus 20 mA), the system routes the incoming signal through the internal 250 Ohm precision shunt resistor. Always match your hardware terminal wiring to the software range configuration to avoid instrument scaling errors.

  • Can this module detect an out-of-bounds or broken field wire condition automatically?

    Yes. The NC1AX04-MR tracks live signal levels continuously. If an external instrument wire breaks or a transmitter suffers an internal component failure that drops the loop current below standard parameters, the module registers an underflow fault condition. It alerts the central F70 CPU via the backplane bus while simultaneously triggering the faceplate fault LEDs to guide maintenance personnel straight to the failed field loop.

  • Does the IP20 enclosure rating mean this module requires an external control cabinet?

    Yes. An IP20 rating means the housing protects personnel from accidental finger contact with internal live circuits, but it does not shield the module from airborne moisture, conductive dust, or corrosive chemical fumes. You must install the MICREX-F backplane and its docked NC1AX04-MR cards inside an appropriately sealed, climate-controlled industrial panel enclosure (such as a NEMA 12 or IP54 cabinet) to ensure long-term equipment reliability.

You may also like