{"product_id":"fuji-electric-dcs-nc1ax04-mr-voltage-current-input-unit","title":"Fuji Electric DCS NC1AX04-MR Voltage Current Input Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Fuji Electric NC1AX04-MR operates as a high-precision, rack-mounted 4-channel multi-range analog input module engineered exclusively for the MICREX-F F70 programmable logic controller (PLC) platform. This high-performance automation component interfaces directly with field sensors, temperature transmitters, and flow meters, converting raw variable electrical currents and voltages into stabilized 12-bit digital values. Control engineers deploy this module inside processing networks to capture rapid instrument changes, utilizing its flexible input ranges to manage diverse signal profiles on a single standardized hardware face.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFuji Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNC1AX04-MR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-Range Analog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFuji MICREX-F \/ F70 PLC Infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eActive Input Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 distinct analog input channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBipolar Voltage Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlus\/minus 10 V, plus\/minus 5 V, plus\/minus 1 V, plus\/minus 0.5 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBipolar Current Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlus\/minus 20 mA, plus\/minus 10 mA, plus\/minus 2 mA, plus\/minus 1 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Processing Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit analog-to-digital converter matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Conversion Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlus\/minus 0.1% of full scale span under typical loads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than or equal to 1 Megohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohms standard internal resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoop Conversion Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms execution time per active channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Circuit Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-integrity channel-to-channel and channel-to-system isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVisual Diagnostic Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated real-time LEDs tracking module and channel health\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Enclosure Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Outer Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mm x 100 mm x 30 mm (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg (1.10 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation Mounting Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlots directly into standard MICREX-F backplane chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Operating Envelope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePermissible Relative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% relative humidity (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGlobal Industry Validations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE marked, UL listed, CSA approved\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEngineering Country of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eComplete Channel-to-Channel Isolation Blocks Destructive Ground Loops\u003c\/h3\u003e\n\u003cp\u003eUnlike lower-tier shared-ground input cards, the NC1AX04-MR incorporates complete galvanic channel-to-channel and channel-to-system electrical isolation. Plant facilities often exhibit significant electrical ground potential differences between widely separated field instruments. This module isolates each input loop entirely, trapping stray common-mode voltages and preventing destructive ground currents from migrating between channels or entering the main MICREX-F backplane bus processor.\u003c\/p\u003e\n\u003ch3\u003eMulti-Range Signal Agility Eliminates Extra Hardware Inventory\u003c\/h3\u003e\n\u003cp\u003eThe onboard input channels accommodate both voltage and current spans, supporting diverse sub-ranges from low-level plus\/minus 0.5V transmitter steps up to standard plus\/minus 20 mA industrial loops. This flexibility allows plant designers to land different signal types onto adjacent terminals of the same 0.5 kg module. By removing the need to source separate dedicated voltage and current cards, this universal profile lowers spare parts inventory overhead.\u003c\/p\u003e\n\u003ch3\u003eSub-Millisecond Conversion Tracking Enhances Closed-Loop Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe high-speed A\/D conversion circuit processes signal states at a rapid rate of 1 ms per channel. This quick performance ensures that real-time process deviations—such as rapid fluid pressure drops or sudden heat spikes—are written to the central F70 processor registers without communication lag. This responsive tracking allows the PLC safety routines and active PID blocks to respond fast, preserving tight control tolerances across delicate chemical, manufacturing, and power cycles.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHow do you configure individual channels on the NC1AX04-MR for voltage versus current modes?\u003c\/p\u003e\n\u003cp\u003eYou select and configure the specific electrical input ranges for each channel via software within the standard Fuji Electric MICREX-F programming toolset. When setting up a channel for a current loop (such as plus\/minus 20 mA), the system routes the incoming signal through the internal 250 Ohm precision shunt resistor. Always match your hardware terminal wiring to the software range configuration to avoid instrument scaling errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module detect an out-of-bounds or broken field wire condition automatically?\u003c\/p\u003e\n\u003cp\u003eYes. The NC1AX04-MR tracks live signal levels continuously. If an external instrument wire breaks or a transmitter suffers an internal component failure that drops the loop current below standard parameters, the module registers an underflow fault condition. It alerts the central F70 CPU via the backplane bus while simultaneously triggering the faceplate fault LEDs to guide maintenance personnel straight to the failed field loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the IP20 enclosure rating mean this module requires an external control cabinet?\u003c\/p\u003e\n\u003cp\u003eYes. An IP20 rating means the housing protects personnel from accidental finger contact with internal live circuits, but it does not shield the module from airborne moisture, conductive dust, or corrosive chemical fumes. You must install the MICREX-F backplane and its docked NC1AX04-MR cards inside an appropriately sealed, climate-controlled industrial panel enclosure (such as a NEMA 12 or IP54 cabinet) to ensure long-term equipment reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43886262255715,"sku":"NC1AX04-MR","price":360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/339_f5d724a7-aa22-4f73-baba-fcf8a1df2cbd.jpg?v=1765522956","url":"https:\/\/www.autocontrolglobal.com\/products\/fuji-electric-dcs-nc1ax04-mr-voltage-current-input-unit","provider":"AutoControl Global","version":"1.0","type":"link"}