GE 362A1052P404 Flame Detector Gas Turbines UV Flame Sensor
GE 362A1052P404 Flame Detector Gas Turbines UV Flame Sensor
GE 362A1052P404 Flame Detector Gas Turbines UV Flame Sensor
/ 3

GE 362A1052P404 Flame Detector Gas Turbines UV Flame Sensor

  • Manufacturer: GE Fanuc

  • Part Number: 362A1052P404

  • Condition:New with Original Package

  • Product Type: Flame Detectors

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE 362A1052P404 Flame Detector

The GE 362A1052P404, also cataloged as the 362A1052P404 UV Flame Sensor, operates as a dedicated hardware component for continuous flame presence detection and optical combustion verification within turbine burner management systems.

Hardware Specifications

Parameter Specification
Model 362A1052P404
Brand GE
Origin United States
Weight 1.0 kg
Dimensions 170 x 105 x 32 mm
Operating Temp -40 to 85 deg C (up to 235 deg C with water cooling)
Power Consumption 24 VDC (12 to 30 VDC operating range, >=100 mA)
Sensing Element Silicon carbide (SiC) photodiode
Spectral Range Dual-spectrum UV (180 to 260 nm) and IR (1.0 to 4.5 um)
Response Time Less than or equal to 25 ms
Output Signals 4-20 mA, RS-485, dry contact alarm
Optical Field 90 deg wide angle, 9 to 15 m detection range
Enclosure Material AISI 316 stainless steel with sapphire window
Process Connection 3/4 inch NPT threaded mount
Protection Class IP65 / IP66, explosion-proof ATEX Zone 2

Backplane Bus Communication Velocity & Network Integration

Engineers integrate the 4-20 mA current loop and RS-485 serial outputs directly into downstream PLC rack IO modules or distributed control architectures to maintain continuous telemetry flow. Internal firmware flash compatibility supports real-time optical intensity scaling, driving analog conversion latencies down to under 25 ms. The sensor transmits discrete diagnostic alarms and analog flame intensity profiles across deterministic network interfaces to ensure instantaneous burner shutdown execution during loss-of-flame fault states.

Frequently Asked Questions

Q: What legacy unit does the GE 362A1052P404 directly replace?

A: The 362A1052P404 serves as a direct functional and mechanical replacement for model number 362A1052P004.

Q: Is external cooling required when operating the sensor at elevated temperatures?

A: For ambient operating environments exceeding 85 deg C, a dedicated water-cooling jacket is required to protect internal photodiode components up to 235 deg C.

Field Installation Guidelines

Thread the 3/4 inch NPT mounting connector onto the turbine sight port until achieving a minimum engagement of 5 full threads to ensure a pressure-tight seal. Align the sapphire optical window toward the primary combustion zone at an angle that avoids direct line-of-sight exposure to uncooled hot refractory walls. Connect the signal wiring shield to a clean panel ground point on one end only to eliminate ground loop interference on the 4-20 mA loop.