  • Manufacturer: GE Fanuc

  • Part Number: D25-936A-9333-3AAA-AA1B1

  • Condition:New with Original Package

  • Product Type: Substation Automation Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE D25-936A-9333-3AAA-AA1B1 Substation Automation Module

The GE D25-936A-9333-3AAA-AA1B1, also cataloged as the D25 Substation Automation Module, operates as a dedicated hardware component for real-time bay control and SCADA integration within electrical substation automation networks. The module executes high-speed data acquisition, breaker interlocking logic, and automated load shedding across distribution and transmission systems. Integrated diagnostic routines continuously evaluate hardware operational states to ensure prompt fault detection and event logging.

Hardware Specifications

Parameter Specification
Model D25-936A-9333-3AAA-AA1B1
Brand GE
Origin Industrial Automation Standard Manufacturing
Weight 0.5 kg
Dimensions 100 mm x 80 mm x 20 mm
Operating Temp -40 to +70 deg C
Power Consumption 24 VDC Nominal Input Voltage
Processor Architecture Modular High-Performance Real-Time CPU
Communication Interfaces Dual Redundant Ethernet Ports, RS-232 / RS-485 Serial Ports
Supported Protocols Modbus TCP/IP, IEC 61850 GOOSE, DNP3.0, IEC 60870-5-103
Functional Execution Real-Time Bay Control, Event Recording, Interlocking Logic

Deterministic Industrial Networking and Firmware Compatibility

The GE D25-936A-9333-3AAA-AA1B1 controller handles backplane bus communication velocity demands by processing deterministic network packets across its dual redundant Ethernet channels. Native support for IEC 61850 GOOSE and DNP3.0 messaging ensures deterministic latency profiles during high-speed switchgear operations. Furthermore, the unit maintains strict firmware flash compatibility across legacy serial sub-networks and modern TCP/IP grid architectures, maintaining system synchronization during complex automation execution cycles.

Frequently Asked Questions

Q: How do the dual redundant Ethernet interfaces function during primary link failure?

A: The onboard network controller continuously monitors physical layer status and instantly shifts packet routing to the secondary Ethernet port without losing active TCP sessions or IEC 61850 GOOSE message streams.

Q: What precautions are required regarding backplane current consumption when scaling module density?

A: Engineers must verify that the 24 VDC rack power supply capacity exceeds the aggregate power draw of all installed modules to prevent voltage droop during peak processing or relay switching cycles.

Q: Can the serial ports operate concurrently with the dual Ethernet channels?

A: Yes, the onboard communications processor independently drives the RS-232 and RS-485 physical transceivers alongside Ethernet controllers, allowing simultaneous execution of legacy DNP3.0 or IEC 60870-5-103 serial loops and Ethernet protocols.

Field Installation Guidelines

Follow these core physical and electrical practices during the mounting and wiring process:

  1. Power Isolation Procedure: Isolate the external 24 VDC power supply before inserting or replacing the controller module to avoid voltage transients across the internal logic backplane.
  2. Chassis Alignment & Grounding: Slide the module into the designated chassis rack guides until the backplane connectors seat completely. Fasten all retaining screws to establish low-resistance chassis ground continuity.
  3. Serial & Ethernet Shielding: Terminate all RS-485 twisted-pair and RJ45 Ethernet cable shields to designated earth ground terminals to eliminate ground loops and mitigate high-frequency noise interference.
  4. Thermal Dissipation Clearance: Maintain an unimpeded vertical clearance of at least 50 mm above and below the rack frame to facilitate natural convection, ensuring ambient air around the chassis remains within the specified -40 to +70 deg C limits.
  5. ESD Mitigation: Personnel must wear grounded electrostatic wrist straps when touching internal board connections or configuring DIP switches to protect high-density silicon components from static discharge.