{"product_id":"ge-ds200pmcbg1kg-mark-v-power-module-control-board","title":"GE DS200PMCBG1KG Mark V Power Module Control Board","description":"\u003ch2\u003eGE DS200PMCBG1KG Mark V Power Module Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200PMCBG1KG\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200PMCBG\u003c\/strong\u003e Power Module Control Board, operates as a dedicated hardware component for distributing regulated DC power, supervising voltage and current levels, and executing backplane communications within GE Mark V Speedtronic platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PMCBG1KG (Base: DS200PMCBG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e280.00 x 200.00 x 25.00 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane supply input +24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, +\/-15 VDC (regulated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (logic-to-power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eBackplane parallel bus to DSPC\/DSPA boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Power Supervision Architecture\u003c\/h3\u003e\n\u003cp\u003eThe board receives raw +24 VDC power from the main rack backplane and converts it into regulated +5 VDC and +\/-15 VDC voltage outputs required by adjacent turbine control cards. Integrated hardware circuits continuously monitor local current draw and line potential to protect downstream electronics against over-voltage, over-current, and thermal overload conditions. The module interfaces directly with DSPC and DSPA processor cards via internal rack paths, using high backplane bus communication velocity to transmit health diagnostics and voltage status. Onboard status LEDs provide instant visual verification of power rail stability, while firmware flash compatibility maintains synchronized operational timing and error logging across the Mark V architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum current output delivered per regulated power channel?\u003c\/p\u003e\n\u003cp\u003eA: The module supplies regulated +5 VDC and +\/-15 VDC power rails with a maximum rating of up to 5 A per channel to drive connected control circuit boards.\u003c\/p\u003e\n\u003cp\u003eQ: How does the DS200PMCBG1KG communicate diagnostic fault conditions to the host controller?\u003c\/p\u003e\n\u003cp\u003eA: The board transmits voltage and current monitoring data across the backplane bus directly to DSPC and DSPA processor boards while illuminating red status LEDs on the board faceplate upon detecting fault conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Can technicians replace the DS200PMCBG1KG module while the rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Live insertion is prohibited due to risk of backplane connector arcing. Maintenance personnel must fully de-energize the main cabinet supply before inserting or extracting the board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, isolate all incoming power sources and verify that the target cabinet is fully de-energized before handling the module. Second, inspect the edge connectors on the rear of the board to confirm that no pins are bent, misaligned, or contaminated. Next, line up the module edges with the card guide channels in the rack, pushing the board smoothly inward until the backplane connectors fully engage. Tighten the top and bottom retaining screws on the front panel to provide mechanical stability and ground contact with the enclosure frame. Finally, restore cabinet power and monitor the front-panel LEDs to verify that output voltage indicators light up green with zero active fault signals.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44638489542755,"sku":"DS200PMCBG1AKG","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/305._e697b90f-d327-4b65-8068-85b74ab9bc99.jpg?v=1789717012","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ds200pmcbg1kg-mark-v-power-module-control-board","provider":"AutoControl Global","version":"1.0","type":"link"}